Measurement and calculation of Ta-182 in a spallation neutron target
Measured and calculated activities of 182Ta in an ISIS spallation neutron target irradiated over five years are compared. The measurements were carried out by gamma-ray spectroscopy through the thick lead walls of a storage flask, and the calculations were carried out using MCNPX and CINDER-90. The...
Gespeichert in:
Veröffentlicht in: | Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment Accelerators, spectrometers, detectors and associated equipment, 2020-05, Vol.961, p.163641, Article 163641 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Measured and calculated activities of 182Ta in an ISIS spallation neutron target irradiated over five years are compared. The measurements were carried out by gamma-ray spectroscopy through the thick lead walls of a storage flask, and the calculations were carried out using MCNPX and CINDER-90. The agreement between measurement and calculation is good. |
---|---|
ISSN: | 0168-9002 1872-9576 |
DOI: | 10.1016/j.nima.2020.163641 |