Analysis methods for highly radiation-damaged SiPMs

Prototype SiPMs with 4384 pixels of dimensions 15×15μm2 produced by KETEK have been irradiated with reactor neutrons to eight fluences between 109 and 5×1014 cm−2. For temperatures between −30∘C and +30∘C capacitance–voltage, admittance–frequency, current–forward voltage, current–reverse voltage and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment Accelerators, spectrometers, detectors and associated equipment, 2020-04, Vol.958, p.162729, Article 162729
Hauptverfasser: Cerioli, S., Garutti, E., Klanner, R., Martens, S., Schwandt, J., Zvolský, M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Prototype SiPMs with 4384 pixels of dimensions 15×15μm2 produced by KETEK have been irradiated with reactor neutrons to eight fluences between 109 and 5×1014 cm−2. For temperatures between −30∘C and +30∘C capacitance–voltage, admittance–frequency, current–forward voltage, current–reverse voltage and charge–voltage measurements with and without illumination by a sub-nanosecond laser have been performed. The data have been analysed using different methods in order to extract the dependence on neutron fluence and temperature of the electrical parameters, the breakdown voltage, the activation energy for the current generation, the dark-count rate and the response to light pulses. The results from the different analysis methods are compared.
ISSN:0168-9002
1872-9576