Paper-based polymeric ionic liquid for thin film micro extraction of sulfonamides in environmental water samples prior to HPLC-DAD analysis
Schematic illustration of p-TFME procedure for Sulfonamide (SAs) analysis. [Display omitted] •New promising paper-based polymer ionic liquid adsorbent for sulfonamides analysis.•The sample preparation of p-TFME method compliance with green analytical chemistry.•Detection of SAs in the environmental...
Gespeichert in:
Veröffentlicht in: | Microchemical journal 2021-12, Vol.171, p.106798, Article 106798 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Schematic illustration of p-TFME procedure for Sulfonamide (SAs) analysis.
[Display omitted]
•New promising paper-based polymer ionic liquid adsorbent for sulfonamides analysis.•The sample preparation of p-TFME method compliance with green analytical chemistry.•Detection of SAs in the environmental water samples prior to liquid chromatography.•Schematic illustration of p-TFME procedure for Sulfonamide (SAs) analysis.
Paper-based polymeric ionic liquid (p-Poly-(MMA-IL)) was successfully developed by grafting the polymeric ionic liquid on the surface of commercial filter paper by using dipping method, presenting a new cost-effective film. The newly developed p-Poly-(MMA-IL) was then applied as a paper-based thin film microextraction (p-TFME) to extract four representative sulfonamides (SAs) drugs, which were sulfadiazine, sulfachloropyridazine, sulfamethoxazole, and sulfadimethoxine in environmental water samples. Besides, p-Poly-(MMA-IL) was successfully characterised by FTIR, FESEM, and XRD techniques and underwent significant parameters optimisation, which affected the extraction efficiency. Under optimal conditions, the proposed method (p-Poly-(MMA-IL)-TFME) was evaluated and applied to analyse SAs in environmental water samples by using a high-performance liquid chromatography-diode array detector (HPLC-DAD). The validation method showed that a good linearity (0.50 µg L-1 –500 µg L-1) was noted (R2 > 0.999, n = 3). Detection and quantification limits were within 0.14 µg L-1 – 0.52 µg L-1 and 0.41 – 1.57 µg L-1, respectively, the preconcentraction factors were > 14.95, and the matrix effect was less than 2.64%, an acceptable percentage for real samples analysis. The extraction recoveries of environmental water samples were ranged from 90.4% to 109.9% with a relative standard deviation (RSD) of less than 9.8%. The newly developed paper-based polymeric ionic liquid (p-Poly-(MMA-IL) for analysis of SAs under the p-TFME procedure was successfully achieved with limited sample volume and organic solvent, fast extraction, and practicable in the daily analysis. |
---|---|
ISSN: | 0026-265X 1095-9149 |
DOI: | 10.1016/j.microc.2021.106798 |