Optimized ion selective electrode for determination of Tamsulosin hydrochloride in the presence of co-formulated Deflazacort in bulk, tablet dosage form and human urine

•Different Ion selective electrodes for determination of Tamsulosin HCl were developed.•Six sensors were fabricated using 3 ion exchangers alternatively with 2 ionophores.•Analysis of Tamsulosin HCl in dosage form and human urine was performed.•The suggested method was fully validated according to I...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Microchemical journal 2021-04, Vol.163, p.105936, Article 105936
Hauptverfasser: Boltia, Shereen A., Abdelkawy, Mohammed, Mohamed, Taghreed A., Mostafa, Nahla N.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•Different Ion selective electrodes for determination of Tamsulosin HCl were developed.•Six sensors were fabricated using 3 ion exchangers alternatively with 2 ionophores.•Analysis of Tamsulosin HCl in dosage form and human urine was performed.•The suggested method was fully validated according to IUPAC guidelines.•The greenness of the developed method was assessed using Analytical Eco- scale which was proposed by Gałuszka et al. Direct analytical methods offer an excellent tool for rapid determination of pharmaceuticals without deviation from the green analytical chemistry principles. In this work, a potentiometric ion selective electrode (ISE) method for the selective determination of the α1A-adrenoceptor blocker, Tamsulosin HCl was developed, optimized and assessed for greenness. Six different PVC-membrane sensors were fabricated using 2-nitrophenyl octyl ether (NPOE) as a plasticizer. Three ion exchangers were used, namely sodium tetraphenyl borate (Na.TPB), sodium tetrakis- [3,5-bis (trifluoro- methyl) phenyl] borate (Na.Tetrakis) and ammonium reineckate (Amm. RK) in exchange with the two ionophores, 4-tert-Butylcalix [8] arene (Calix.) and 2-hydroxypropyl-β-cyclodextrin (β-CD). The electrochemical responses of all sensors were studied and recorded. The sensor which consisted of sodium tetraphenyl borate as ion exchanger and 4-tert-Butylcalix [8] arene as ionophore was selected for application to analysis of Tamsulosin HCl in dosage form and human urine. The electrochemical performance characteristics of the electrode were validated as per IUPAC recommendations. Analytical Eco Scale assessment was used for evaluation of the greenness of the method and compared with the USP official method for the determination of Tamsulosin HCl.
ISSN:0026-265X
1095-9149
DOI:10.1016/j.microc.2021.105936