Electrospun PVA/TiC Nanofibers for High Performance Capacitive Humidity Sensing

•Synthesis of polymeric PVA/TiC nanofibers by reinforcing TiC NPs into the polyvinyl alcohol matrix.•Development of humidity sensor by electrospinning technique.•Developed sensors demonstrate excellent humidity sensing properties.•Sensors exhibit fast response and recovery time with high sensitivity...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Microchemical journal 2020-09, Vol.157, p.104974, Article 104974
Hauptverfasser: Mazhar, Sadaf, Qarni, Awais Ali, Haq, Yasir Ul, Haq, Zeeshan ul, Murtaza, Imran, Ahmad, Naeem, Jabeen, Nida, Amin, Shahid
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•Synthesis of polymeric PVA/TiC nanofibers by reinforcing TiC NPs into the polyvinyl alcohol matrix.•Development of humidity sensor by electrospinning technique.•Developed sensors demonstrate excellent humidity sensing properties.•Sensors exhibit fast response and recovery time with high sensitivity and humidity detection limit from 1-90 %RH.•These characteristics provide fabulous opportunities for various practical uses e.g. personal health and activity monitoring. In this work, high performance capacitive type humidity sensors are fabricated based on polymeric PVA/TiC nanofibers by reinforcing TiC NPs into the polyvinyl alcohol matrix following the most cost-effective electrospinning technique. The fabricated nanofibers are then characterized by SEM, XRD and FTIR which reveal the strong bonding interaction of both the precursors. The humidity sensing capability of PVA/TiC nanofibers mat is determined at room temperature in the frequency range of 100 Hz - 100 kHz. The fabricated humidity sensor displays an excellent capacitive humidity response in terms of linear capacitive behavior, short response/recovery time of 2.8/1.7 s, high sensitivity of 1,277,355.0%, good repeatability and excellent stability, at the frequency of 100 Hz. Moreover, in the humidification and dehumidification cycle, the sensor exhibits a small hysteresis of 2.8% at 100 Hz. The fabricated nanofibers-based sensor also indicates high sensitivity to every 1% RH variation from 1% to 90% RH. These favorable characteristics of PVA/TiC nanofibers enable the fabricated humidity sensor to determine the human respiration and can differentiate between slow and fast breath from the nose and mouth or before and after the exercise, respectively.
ISSN:0026-265X
1095-9149
DOI:10.1016/j.microc.2020.104974