An improved technique for quantifying PD activity in cross-linked polyethylene (XLPE) power cables
The presence of air-filled cavities within the insulation of active power cables affects the electric field distribution in the insulation bulk and increases the electrical stress inside and around the cavities. This causes accelerated ageing of the materials and creates regions for partial discharg...
Gespeichert in:
Veröffentlicht in: | Measurement : journal of the International Measurement Confederation 2023-04, Vol.211, p.112633, Article 112633 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The presence of air-filled cavities within the insulation of active power cables affects the electric field distribution in the insulation bulk and increases the electrical stress inside and around the cavities. This causes accelerated ageing of the materials and creates regions for partial discharge (PD) development that may subsequently result in cable failure. In this paper, an improved PD quantifying technique applied for insulated power cables is first presented. Its effectiveness is demonstrated through an in-depth study of electric field distribution across a defective cross-linked polyethylene (XLPE) power cable with practical dimensions for HV applications and by analysing the PD behaviour under different ageing conditions. In realizing the aforementioned, the cable model with different arrangements, in series and parallel, of two discharging air-filled cavities was implemented in COMSOL software. The simulated cable fields are analysed for different separations and positions of the cavities before and after PD activity. The cavity fields are extracted in MATLAB and utilized for PD pattern characterization under three ageing conditions. Through the PD patterns and statistical quantities measured from simulated PD behaviour, the severity of PD in the cable model was quantified over the different ageing periods. It was found that the series configuration of the cavities was the most harmful configuration due to its high-field magnitude and greater tendency to initiate a PD propagation. Furthermore, the PD behaviour changes during ageing and the highest PD activity, greater PD magnitude and rate, were recorded at the most advanced ageing stage. Thus, indicating that PD characteristics can be used for inferring the ageing stage.
•The electric field distribution across the insulation of an XLPE power cable having two discharging cavities is presented.•The electric field is simulated and analysed for parallel and serial arrangements of the air-filled cavities before and after the first PD event.•With about 68.3% field increments to the cable insulation, the series configuration of the cavities was found to be the most harmful.•For both series and parallel arrangements, the highest PD activity was recorded at the last stage with a PD magnitude of 63.17pC and PD number per cycle of 16.98.•Improved techniques were used to obtain PRPD patterns from the PD models to accurately quantify the PD. |
---|---|
ISSN: | 0263-2241 1873-412X |
DOI: | 10.1016/j.measurement.2023.112633 |