Development of an UHPLC-diode arrays detector (DAD) method for the analysis of polydatin in human plasma
[Display omitted] •Development and validation of UHPLC analytical method for the characterization of polydatin bioavailability.•Average recovery higher than 98 %.•Sensitivity in the nanomolar range.•Fast detection and separation of polydatin and resveratrol in human plasma and urine.•Application of...
Gespeichert in:
Veröffentlicht in: | Journal of pharmaceutical and biomedical analysis 2021-05, Vol.198, p.113985, Article 113985 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | [Display omitted]
•Development and validation of UHPLC analytical method for the characterization of polydatin bioavailability.•Average recovery higher than 98 %.•Sensitivity in the nanomolar range.•Fast detection and separation of polydatin and resveratrol in human plasma and urine.•Application of the method for pharmacokinetic characterization of dietary supplements in human.
A new chromatographic method by Ultra High Performance Liquid Chromatographic (UHPLC) technology, has been developed and validated for the determination of polydatin and resveratrol, as potential metabolite, in human plasma. After the optimization of the chromatographic conditions, the method has been validated on spiked human plasma samples. The optimized extraction allowed to obtain analytes recovery up to 98.48 ± 4.03 %. Then, the isocratic elution in reversed phase mode, provides the separation of polydatin and resveratrol in less than 10.0 min. Chromatographic analysis was performed on a C18, 10 cm x 3.0 mm, 2.7 μm stationary phase, by using triethanolamine phosphate solution (0.1 M, pH = 3.7) and ACN 85:15 (v/v) as mobile phase at a flow rate of 0.5 mL/min. The UV detector was set at 306 nm for the analysis of both polydatin and resveratrol. The limit of detection (LoD) and the limit of quantification (LoQ) for polydatin in plasma samples were found to be 7.82 ± 0.38 nM and 26.06 ± 1.28 nM respectively. The method was found to be accurate and precise with a coefficient for intra- and inter-day variation below 5 %. All the reported data demonstrate how the developed method is rapid and sensitive. Moreover, results of the analysis of plasma samples, obtained from orally treated volunteers with nutritional supplements containing polydatin, have shown the method to be suitable for the pharmacokinetic characterization of polydatin and resveratrol, as metabolite, in humans. |
---|---|
ISSN: | 0731-7085 1873-264X |
DOI: | 10.1016/j.jpba.2021.113985 |