Twisted tapes in solar chimney-earth air heat exchangers for equipment downsizing and passive cooling
Harnessing solar and geothermal energy in hot and arid climates is an effective strategy to reduce building energy consumption. This research investigates integrating Twisted Tapes (TT) into Earth Air Heat Exchanger (EAHE) pipes within a Solar Chimney (SC)-EAHE system, aiming to reduce EAHE pipe len...
Gespeichert in:
Veröffentlicht in: | Journal of Building Engineering 2024-12, Vol.98, p.111128, Article 111128 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Harnessing solar and geothermal energy in hot and arid climates is an effective strategy to reduce building energy consumption. This research investigates integrating Twisted Tapes (TT) into Earth Air Heat Exchanger (EAHE) pipes within a Solar Chimney (SC)-EAHE system, aiming to reduce EAHE pipe length while meeting ventilation requirements and decreasing cooling demand. Two key innovations are introduced: first, this study pioneers the integration of TT into a SC-EAHE system; second, it comprehensively explores TT geometry optimization, analyzing the effects of width ratio and rotation rate across 77 configurations. Numerical simulations are conducted in ANSYS Fluent using the k-ε RNG turbulence model to investigate thermal performance and airflow characteristics. Findings reveal that TT integration results in a 153 % increase in Nusselt number. Additionally, it is shown that a 1 m SC diameter achieves ventilation of 4.8 Air Changes per Hour (ACH) using TT with a width ratio and rotation rate of 0.5, while reducing EAHE pipe length by 2.6 %. Increasing the SC diameter to 1.25 m, with a TT width ratio of 0.6 and rotation rate of 1.25, leads to a 13 % (35 m) reduction in EAHE pipe length while meeting a minimum outlet temperature of 290.15 K and ACH requirements. However, the benefit diminishes beyond a 1.25 m SC diameter. This study contributes to understanding of integrating TT into SC-EAHE systems, addressing the critical need for sustainable energy solutions and offering a novel and energy-efficient approach for passive cooling in extreme climates.
[Display omitted]
•A method to downsize underground heat exchangers for buildings using twisted tapes.•Twisted tapes boost thermal performance of Solar Chimney-Earth Air Heat Exchangers.•Optimal twisted tapes geometry downsized the Earth Air Heat Exchanger pipes by 13 %.•Proposed system fulfills ventilation criteria and reduces peak temperature loads.•Twisted tapes improve passive cooling efficiency of Earth Air Heat Exchangers. |
---|---|
ISSN: | 2352-7102 2352-7102 |
DOI: | 10.1016/j.jobe.2024.111128 |