Study of the situation deduction of a domino accident caused by overpressure in LPG storage tank area

The production and storage of liquefied petroleum gas (LPG) is gradually becoming larger and more intensive, which greatly increases the risk of the domino effect of an explosion accident in a storage tank area while improving production and management efficiency. This paper describes the constructi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of loss prevention in the process industries 2021-09, Vol.72, p.104525, Article 104525
Hauptverfasser: Jinlong, Men, Hongbing, Ji, Zhitao, Chen, Wenli, Xie, Lingbo, Zhang
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The production and storage of liquefied petroleum gas (LPG) is gradually becoming larger and more intensive, which greatly increases the risk of the domino effect of an explosion accident in a storage tank area while improving production and management efficiency. This paper describes the construction of the domino effect scene of an explosion accident in an LPG storage tank area, the analysis of the characteristics of the LPG tank explosion shock wave and the target storage tank failure, and the creation of an ANSYS numerical model to derive the development trend and expansion law of the domino accident in the LPG storage tank area. The research showed that: 400 m3 tank T1 explosion shock waves spread to T2, T4, T5, T3, and T6, and the tank overpressures of 303 kPa, 303 kPa, 172 kPa, 81 kPa, and 61 kPa respectively. The critical values of the target storage tank failure overpressure-range threshold were 70 kPa and 60 m. After the explosion of the initial unit T1 tank, at 38 ms, the T2 and T4 storage tanks failed and exploded; at 56 ms, the T5 storage tank exploded for the third time; at 82 ms, the T3 storage tank exploded for the fourth time; and at 102 ms, the T6 storage tank exploded for the fifth time. With the increase of explosion sources, the failure overpressure of the target storage tank increased, and the interval between explosions continuously shortened, which reflected the expansion effect of the domino accident. The domino accident situation deduction in the LPG storage tank area provided a scientific basis for the safety layout, accident prevention and control, emergency rescue, and management of a chemical industry park. •The explosion of the 400 m3 LPG tank was sufficient to cause the tank to fail in the mid near field(10–25 m).•The failure of the target storage tank in the middle and far field is greatly affected by two or more explosion sources.•The maximum superimposed shock wave propagates along the line direction of the source of the explosion.•With the increase of explosion sources, the overpressure of storage tank increases and explosion interval time decreases.
ISSN:0950-4230
DOI:10.1016/j.jlp.2021.104525