In-situ fabrication of tungsten oxide film pH micro-sensor and its application on the pH monitoring of Fe-Cu galvanic corrosion

•W/WOx-pH micro-sensor is in-situ fabricated on UME using constant current anodizing.•Micro-sensor shows good linearity, sensitivity and anti-interference in solutions.•Both anodic and cathodic sites appear on Fe surface under galvanic effect with Cu. Localized and interface pH values are important...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of electroanalytical chemistry (Lausanne, Switzerland) Switzerland), 2024-06, Vol.962, p.118259, Article 118259
Hauptverfasser: Xiao, Yu-Hua, Huang, Qiu-Yu, Wang, Jian, Li, Xin-Ran, Zhu, Ze-Jie, Zhang, Qin-Hao, Cao, Fa-He
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•W/WOx-pH micro-sensor is in-situ fabricated on UME using constant current anodizing.•Micro-sensor shows good linearity, sensitivity and anti-interference in solutions.•Both anodic and cathodic sites appear on Fe surface under galvanic effect with Cu. Localized and interface pH values are important parameters for studying the corrosion progress and complex interface reactions. Although commercial glass pH sensors have been widely used to measure solution pH value due to their advantages of long stability and high sensitivity, they were unable to determine the interface and microregion pH value for their difficulty in miniaturization. In this work, an all-solid-state pH micro-sensor with strong adhesion strength was in-situ fabricated on diameter 15 μm tungsten ultramicroelectrode (UME) using constant current anodizing. The pH micro-sensor showed good linear response (R2 = 0.999), excellent sensitivity (with a slope of −53.8 mV/pH), quick response (44 days) and great anti-interference ability to most of the ions in marine (selectivity coefficients pKij > 7), such as SO42−, Cl−, NO3−, K+, Mg2+ and Fe2+. Then, the pH micro-sensor, combined with the potentiometric mode of SECM, was further employed to explore the localized pH value distribution during the galvanic corrosion of Fe-Cu couple in 0.1 M NaCl solution. To further verify the anti-interference ability of pH micro-sensor, potentiometric SECM experiment was also conducted in artificial seawater. Results showed that both acidic sites and alkalizing sites appeared on the Fe surface, while homogeneous alkalization took place overall Cu surface. This was consistent with the SVET results that anodic and cathodic areas existed simultaneously on Fe surface. Thus, it could be concluded that local corrosion occurred on Fe surface and only part of the Fe surface acted as the anodic even under galvanic effect. However, Cu acted as cathode with the homogeneously distributing cathodic current on the whole surface during the galvanic corrosion.
ISSN:1572-6657
1873-2569
DOI:10.1016/j.jelechem.2024.118259