Single-stage NBI sampler for PM1 mass and five-stage NBI-NMCI sampler for PM1 mass distribution measurements

In recent years, concerns about the health and environmental risks associated with PM1 particles have increased. However, existing PM1 sampling instruments remain to be improved mainly because their PM1 inlets have particle loading and bounce issues. To address these challenges, PM1 inlets based on...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of aerosol science 2025-01, Vol.183, p.106479, Article 106479
Hauptverfasser: Le, Thi-Cuc, Tsai, Yao-Yu, Wang, Chia C., Tsai, Chuen-Jinn
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In recent years, concerns about the health and environmental risks associated with PM1 particles have increased. However, existing PM1 sampling instruments remain to be improved mainly because their PM1 inlets have particle loading and bounce issues. To address these challenges, PM1 inlets based on the Non-Bouncing Impactor (NBI) technique were developed. These inlets employ vacuum oil-wetted glass fiber filter (GFF) substrates to eliminate particle bounce and incorporate a daily vacuum oil injection to prevent particle loading. The 16.7 L/min PM1 NBI, modified from the PM2.5 M-WINS design with a reduced diameter of the single nozzle, was designed to adapt readily with current standard sampling and monitoring systems. The cut-size (Dpa50) of 0.99 ± 0.02 μm was determined by considering the effects of Reynold number and the ratio of jet-to-plate distance and nozzle diameter. Field tests comparing the 16.7 L/min PM1 NBI sampler to the 9-stage NCTU Micro-orifice Cascade Impactor (NMCI9) revealed small sampling biases, with a mean difference of +0.26 ± 2.28 μg/m3 for PM1 measurements when silicone oil-coated aluminum foil (AF) and GFF-AF were used in the NMCI9. The NBI with the oil-wetted GFF substrate effectively removed particles larger than 1.0 μm, resulting in more accurate PM1 mass concentration measurements. Additionally, the development of a 5-stage NMCI with the 30 L/min PM1 NBI as the first stage enabled detailed measurement of PM1 mass distribution in two modes, which was challenging when measuring the entire mass distribution of ambient aerosols. The distribution of size-dependent water-soluble inorganic ions in PM1 showed dominance of SO42− and NH4+ in PM1 compared to PM2.5. In summary, the PM1 NBI enhances accuracy for long-term atmospheric sampling by addressing particle loading and bounce, making it a more reliable standard sampling instrument. [Display omitted] •A 16.7 L/min Non-Bouncing Impactor (NBI) was developed with excellent cutoff characteristics (Dpa50 = 0.99 μm).•The 16.7 L/min NBI can easily replace the existing PM2.5 inlets and adapt readily to the current FRM samplers and FEM monitors.•The 30 L/min NBI was developed and used as the first stage of a 5-stage cascade impactor to remove particles larger than 1.0 μm.•The 5-stage NMCI-NBI enables detailed measurement of PM1 mass distribution in two modes and its chemical composition.
ISSN:0021-8502
DOI:10.1016/j.jaerosci.2024.106479