A glassy carbon electrode modulated with Poly (Naphthol green B) for simultaneous electroanalysis of serotonin and Epinephrine in presence of l-tryptophan

[Display omitted] •p-NGB/MGCE was fabricated by simple electropolymerisation process.•The customised sensor accelerates the electrocatalytic current response with reduced overvoltage for SE and EP.•Modified electrode exhibits excellent selectivity, sensitivity and stability.•The wide linear rage and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Inorganic chemistry communications 2022-11, Vol.145, p.110013, Article 110013
Hauptverfasser: banu, Rukaya, Kumara Swamy, B.E., Ebenso, Eno
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:[Display omitted] •p-NGB/MGCE was fabricated by simple electropolymerisation process.•The customised sensor accelerates the electrocatalytic current response with reduced overvoltage for SE and EP.•Modified electrode exhibits excellent selectivity, sensitivity and stability.•The wide linear rage and lower detection limit was attained at p-NGB/MGCE.•Concurrent resolution of 5-HT, EP and LT was achieved. Present study reports the simplified and efficient method for the quantification of Serotonin(5-HT)and Epinephrine(EP) by using a glassy carbon electrode customised with poly(Naphthol green B) film. The electrochemical measurements were performed through cyclic and differential pulse voltammetry. The experimental outcomes authenticates that the developed sensor accelerates the electrocatalytic current response with reduced overvoltage for 5-HT and EP. The operating system and certain experimental variables includes Sweep rate, differed pH values of supporting medium and the impact of varying concentration of 5-HT and EP were adjusted. The sweep rate study reveals the diffusion controlled kinetics for 5-HT and EP at P-NGB/MGCE. At the optimum reaction conditions, the fabricated electrode exhibits the linear behaviour in the concentration range of 0.1 × 10-4M to 0.8 × 10-4M and 0.1 × 10-4M to 1 × 10-4 M with the lower limit of detection of 2.3 μM & 1.3 μM for 5-HT and EP respectively. The selectivity of the constructed electrode was achieved by concurrent determination of 5-HT and EP in presence of l-Tryptophan(LT). This provides the advantageous of the fabricated sensor as it shows good sensibility, convenient method for fabrication and excellent selectivity for specific and simultaneous study of 5-HT and EP.
ISSN:1387-7003
1879-0259
DOI:10.1016/j.inoche.2022.110013