Systematic evaluation of design features enables efficient selection of Π electron-stabilized polymeric micelles

[Display omitted] Polymeric micelles (PM) based on poly(ethylene glycol)-b-poly(N-2-benzoyloxypropyl methacrylamide) (mPEG-b-p(HPMA-Bz)) loaded with paclitaxel (PTX-PM) have shown promising results in overcoming the suboptimal efficacy/toxicity profile of paclitaxel. To get insight into the stabilit...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of pharmaceutics 2020-06, Vol.584, p.119409, Article 119409
Hauptverfasser: Sheybanifard, Maryam, Beztsinna, Nataliia, Bagheri, Mahsa, Buhl, Eva Miriam, Bresseleers, Jaleesa, Varela-Moreira, Aida, Shi, Yang, van Nostrum, Cornelus F., van der Pluijm, Gabri, Storm, Gert, Hennink, Wim E., Lammers, Twan, Metselaar, Josbert M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:[Display omitted] Polymeric micelles (PM) based on poly(ethylene glycol)-b-poly(N-2-benzoyloxypropyl methacrylamide) (mPEG-b-p(HPMA-Bz)) loaded with paclitaxel (PTX-PM) have shown promising results in overcoming the suboptimal efficacy/toxicity profile of paclitaxel. To get insight into the stability of PTX-PM formulations upon storage and to optimize their in vivo tumor-targeted drug delivery properties, we set out to identify a lead PTX-PM formulation with the optimal polymer composition. To this end, PM based on four different mPEG5k-b-p(HPMA-Bz) block copolymers with varying molecular weight of the hydrophobic block (17–3 kDa) were loaded with different amounts of PTX. The hydrodynamic diameter was 52 ± 1 nm for PM prepared using polymers with longer hydrophobic blocks (mPEG5k-b-p(HPMA-Bz)17k and mPEG5k-b-p(HPMA-Bz)10k) and 39 ± 1 nm for PM composed of polymers with shorter hydrophobic blocks (mPEG5k-b-p(HPMA-Bz)5k and mPEG5k-b-p(HPMA-Bz)3k). The best storage stability and the slowest PTX release was observed for PM with larger hydrophobic blocks. On the other hand, smaller sized PM of shorter mPEG5k-b-p(HPMA-Bz)5k showed a better tumor penetration in 3D spheroids. Considering better drug retention capacity of the mPEG5k-b-p(HPMA-Bz)17k and smaller size of the mPEG5k-b-p(HPMA-Bz)5k as two desirable design features, we argue that PM based on these two polymers are the lead candidates for further in vivo studies.
ISSN:0378-5173
1873-3476
DOI:10.1016/j.ijpharm.2020.119409