An improved compensation method for voltage sags and swells of the electric vehicles charging station based on a UPQC-SMES system
•The proposed EVCS is based on the UPQC-SMES system.•A V2G-based UPQC-VAmin compensation method is proposed for voltage regulation.•The proposed method can effectively protect the grid during sags or swells.•The power flow analysis of the EVCS system with the proposed method is performed.•The reliab...
Gespeichert in:
Veröffentlicht in: | International journal of electrical power & energy systems 2022-12, Vol.143, p.108501, Article 108501 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | •The proposed EVCS is based on the UPQC-SMES system.•A V2G-based UPQC-VAmin compensation method is proposed for voltage regulation.•The proposed method can effectively protect the grid during sags or swells.•The power flow analysis of the EVCS system with the proposed method is performed.•The reliability and effectiveness of the research are verified by simulation.
The immaturity of electric vehicles (EVs) in voltage regulation and the inconsistency of multiple vehicle-to-grid (V2G) functions are the issues that need to be addressed in V2G technology applications. To simultaneously deal with these issues, this paper proposes an electric vehicles charging station (EVCS) based on a unified-power-quality-conditioner-superconducting-magnetic-energy-storage (UPQC-SMES) system. The EVCS based on UPQC-SMES can regulate the regular power disturbances like the load current harmonics and grid voltage distortions. For voltage sags and swells, an improved compensation method based on V2G is proposed to enhance the protection of the faulty grid. It can be classified into 1) Mode 1, to regulate the power profile of the faulty grid with the maximum capability of the EVCS; 2) Mode 2, to minimize the volt-ampere (VA) loading of the UPQC with a specific compensation power and voltage injection angle which are related to the load impedance angle and fault level. A complete power flow analysis of the system is carried out combined with phasor diagrams, especially under the operation of the proposed method. Simulation results show that the modifications of EVs in the V2G mode can effectively mitigate the overcurrent and overvoltage during sags and swells. The feasibility and desirable dynamic characteristics of the proposed method are demonstrated by simulation, and the adopted 1.193-H/0.462-MJ SMES suppresses power fluctuations and stabilizes the DC-side voltage effectively. It ensures stable operation of the UPQC and a superior charging environment for the EVCS. |
---|---|
ISSN: | 0142-0615 1879-3517 |
DOI: | 10.1016/j.ijepes.2022.108501 |