The concept of direct adaptive control for improving voltage and frequency regulation loops in several power system applications
•The concept of direct adaptive control has been employed in three applications: the Egyptian power system, a three-area interconnected MG, and a single machine connected to the grid.•A modified virtual rotor (inertia + damping) has been suggested for EPS and 3-area MG frequency regulation.•A new se...
Gespeichert in:
Veröffentlicht in: | International journal of electrical power & energy systems 2022-09, Vol.140, p.108068, Article 108068 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | •The concept of direct adaptive control has been employed in three applications: the Egyptian power system, a three-area interconnected MG, and a single machine connected to the grid.•A modified virtual rotor (inertia + damping) has been suggested for EPS and 3-area MG frequency regulation.•A new secondary automatic voltage regulator (AVR) has been added to the excitation system to generate a stable tracking process for reference voltage.•The parameters of virtual inertia, virtual damping, PID gains of PSS and integral controller gain of secondary AVR are adaptively tuned using the HHO optimizer.•The proposed control strategy can efficiently deal with system difficulties such as 3-φ short-circuit fault, load variations, and partial and full injection of solar PV farm, and random loads.
This article presents the idea of direct adaptive control for several power system applications such as the Egyptian power system (EPS), a three-zone interconnected microgrid (MG), and a single machine connected to the grid (SMIB). The main concept of the proposed adaptive method is built on the tuning of the controller gains using Harris hawks optimizer (HHO). In order to maintain the frequency and voltage at their nominal values, a modified virtual rotor (virtual inertia + virtual damping) is investigated as a tertiary control loop within the proposed EPS and the 3-area MG system. For SMIB application, a secondary automatic voltage regulator (AVR) has been added to the primary AVR within the excitation system to offer more adequate damping characteristics for the synchronous generator of the studied system. Where the proportional-integral-derivative power system stabilizer (PID-PSS) is connected to the excitation system for a single machine tied to the grid to significantly mitigate low-frequency oscillations due to various expected faults and undesirable operating conditions. The proposed direct adaptive control strategy has been used to tune the integral controller of the secondary AVR and PID for SMIB application, and also to adjust the virtual rotor in the EPS and the 3-area MG applications. The operative performance of the introduced adaptive secondary AVR is assessed against the conventional system (no PSS), Lead-Lag PSS, and PSS type 2 based PSO and WECC standard under the effect of a 3-φ short-circuit fault subjected at the grid bus considering solar photovoltaic (PV) farm-based grid. Moreover, the EPS system and 3-area MG are evaluated under the effect of load cha |
---|---|