Ignition and combustion of a group of waste-derived fuel slurry droplets: Mutual influence upon low-temperature convective heating
[Display omitted] •Simultaneous ignition occurred at a distance between the droplet centers of 3–5 mm.•At low temperatures, increasing the distance between droplets eliminates synergism.•The use of an oil additive (5%) reduced the ignition delay time of droplets by 15–20%.•The increase in air flow v...
Gespeichert in:
Veröffentlicht in: | Fuel (Guildford) 2023-09, Vol.348, p.128578, Article 128578 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | [Display omitted]
•Simultaneous ignition occurred at a distance between the droplet centers of 3–5 mm.•At low temperatures, increasing the distance between droplets eliminates synergism.•The use of an oil additive (5%) reduced the ignition delay time of droplets by 15–20%.•The increase in air flow velocity contributed to the formation of a common flame zone.•The ignition delay in the droplet group increased with an increase in air flow velocity.
Waste-derived slurries can be burned both in a fluidized bed and when injected into a boiler furnace. This paper is the first to analyze the dynamic characteristics of ignition and combustion of a group of three slurry droplets based on coal slime, water, and waste industrial oil in a low-temperature air flow with a temperature of 500–600 °C and velocity of 0.1–1.2 m/s. The distance between the droplet centers varied from 3 to 15 mm. The results of the study can develop innovative technologies for flare and fluidized bed combustion of fuel slurries at the boiler start-up stage. It was found that a distance of 3–5 mm between droplet centers provides almost simultaneous gas-phase ignition of all droplets. A further increase in the distance critically worsened the ignition and combustion and eliminated the synergy. An increase in the air flow velocity contributed to the appearance of a common flame zone but at the same time increased the ignition delay of droplets by a factor of 1.2–1.6. The negative effects of cooling and entrainment of combustion products by a low-temperature flow can be effectively reduced by adding 5 wt% of industrial oil to the slurry. Also, the use of oil reduced the droplet ignition delay time by 15–20%. At the stages of flame and heterogeneous combustion, the differences for droplets in a group increased (the stage durations differed by 1.5–3 times). For the low-temperature start-up of a boiler, it was found advisable to provide a droplet flow with a sufficient density to stabilize their ignition without significant flow deviations (dimensionless distance 1.5–2.5). |
---|---|
ISSN: | 0016-2361 1873-7153 |
DOI: | 10.1016/j.fuel.2023.128578 |