Prerequisites of inspection conditions for uniform post-mortem inspection in broiler chicken slaughterhouses in Finland
Meat inspection of broiler chickens (broiler) in the European Union is regulated by common legislation to secure meat safety. However, the legislation is general in nature and proper post-mortem inspection (PMI) of every carcass and visceral organs of broilers is challenging in slaughterhouses (SHs)...
Gespeichert in:
Veröffentlicht in: | Food control 2021-12, Vol.130, p.108384, Article 108384 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Meat inspection of broiler chickens (broiler) in the European Union is regulated by common legislation to secure meat safety. However, the legislation is general in nature and proper post-mortem inspection (PMI) of every carcass and visceral organs of broilers is challenging in slaughterhouses (SHs) with a high slaughter line speed. The aim of this study was to investigate the on-site organization and possible differences of the PMI in four Finnish SHs, which slaughter over 99% of broilers in Finland. Our results show that the meat inspector's available inspection time per broiler in the PMI varied between 0.28 and 0.90 s, with the shortest available inspection time in the SH with the highest slaughter line speed and the longest available inspection time in the SH with the slowest line speed. We observed that only part of the total inspection time per broiler could be used for true PMI in most (3/4) SHs, as the meat inspectors also performed other tasks during the PMI. We observed deficiencies in the visual inspection of broiler carcasses; in particular, the proper inspection of all or most of the body cavities was impossible in all SHs during the PMI. Some deficiencies in facilities (e.g. in recording system) were observed. Moreover, lighting properties varied between the SHs and a significant difference between illumination conditions at the first inspection stations in the SHs was observed. This study considered the prerequisites for proper PMI and revealed that the PMI of broilers was not completely uniform in Finland. The results emphasize the need for more precise guidelines and recommendations, especially for inspection time and lighting at inspection stations.
•A short post-mortem inspection time may hamper detection of non-acceptable broilers.•Differences in facilities and lighting affected post-mortem inspection uniformity.•Measurements can be used to evaluate the uniformity of meat inspection stations.•The high line speed of slaughterhouses hinders proper inspection of body cavities. |
---|---|
ISSN: | 0956-7135 1873-7129 |
DOI: | 10.1016/j.foodcont.2021.108384 |