An experimental study of boiling two-phase flow in a vertical rod bundle with a spacer grid. Part 1: Effects of mass flux and heat flux

•X-ray CT experiments are performed for boiling flow in a 3 × 3 rod bundle with a spacer.•High-resolution data on the void fraction distribution are obtained.•The influence of mixing vanes, mass and heat fluxes is investigated.•The effect of heat flux is more remarkable at high mass flux than at low...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Experimental thermal and fluid science 2023-07, Vol.145, p.110903, Article 110903
Hauptverfasser: Taş, Sibel, Boden, Stephan, Franz, Ronald, Liao, Yixiang, Hampel, Uwe
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•X-ray CT experiments are performed for boiling flow in a 3 × 3 rod bundle with a spacer.•High-resolution data on the void fraction distribution are obtained.•The influence of mixing vanes, mass and heat fluxes is investigated.•The effect of heat flux is more remarkable at high mass flux than at low mass flux.•The mixing vanes cause bubble accumulation even at high mass flux or low heat flux. We conducted boiling flow experiments in a 3 × 3 rod bundle containing a spacer grid with split type mixing vanes where the central rod was heated. Void fraction around the spacer grid was measured with high-resolution X-ray computed tomography. The study focusses on the effects of mass and heat flux on the void fraction downstream of the spacer for mass flux and heat flux ranging from 535 to 1950 kg/m2 s and 42.8 to 107.2 kW/m2, respectively. As the working fluid, refrigerant Octafluorocyclobutane (RC 318) was used and fluid scaling was applied. We found that the void fraction increases as the flow passes through the vanes and then decreases downstream until Z≈4Dh, and then increases again. In addition, we found that the mixing vanes cause a local increase in void fraction even at low heat flux or high mass flux, and that the arrangement of the vanes influences the size and location of the high and low void content regions. We also found that the effect of heat flux on the relative void fraction is more noticeable at high mass flux than at low mass flux. In the second part of the study, which will be presented in a separate paper, we investigated the effect of different vane angles on the void fraction.
ISSN:0894-1777
DOI:10.1016/j.expthermflusci.2023.110903