Energy and economic analysis of a variable-geometry ejector in solar cooling systems for residential buildings
•Two 1D models of an ejector using EES and MATLAB were developed.•The performance of the variable area ejector in solar cooling was studied.•The coefficient of performance of the new cycle was improved.•An economic analysis of the solar ejector system was conducted.•The payback period of the new sys...
Gespeichert in:
Veröffentlicht in: | Journal of energy storage 2020-02, Vol.27, p.101061, Article 101061 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | •Two 1D models of an ejector using EES and MATLAB were developed.•The performance of the variable area ejector in solar cooling was studied.•The coefficient of performance of the new cycle was improved.•An economic analysis of the solar ejector system was conducted.•The payback period of the new system is lower than that of the conventional one.
In the present, study two 1-D ejector mathematical models are used to predict the performance of a solar ejector cooling system with fixed and variable geometry ejectors. Thes models are implemented using MATLAB and EES Software. The effect of the mixing efficiencies on the performance of the system was investigated, and two empirical correlations were obtained using experimental data for an ejector cooling cycle with R141b as a refrigerant. The results obtained with varying efficiencies were found to be significantly more accurate than those obtained with previous models, which assumed a constant efficiency. The results showed that the ejector with fixed-geometry was very sensitive to the variations of the operational conditions and could practically be functional only under specific conditions. It was also found that the solar ejector cooling system with a variable area ejector has higher coefficient of performance under a vast range of operational conditions. The new system could be easily implemented in residential building air conditioning systems with solar energy as the driving source of heat. The refrigerant R134a was found to give the best performance considering operational, safety, and environmental factors. The economic analysis revealed that the new system is profoundly better than the conventional systems in terms of payback period and net present value. |
---|---|
ISSN: | 2352-152X 2352-1538 |
DOI: | 10.1016/j.est.2019.101061 |