Optimal placement of uPMUs to improve the reliability of distribution systems through genetic algorithm and variable neighborhood search
•New approach to optimal placement of uPMUs aiming to improve system reliability.•Only two uPMUs are needed to achieve an acceptable resolution in fault location.•A mathematical formulation to quantify the improvement in the system reliability.•Genetic algorithm and variable neighborhood search solv...
Gespeichert in:
Veröffentlicht in: | Electric power systems research 2024-11, Vol.236, p.110910, Article 110910 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | •New approach to optimal placement of uPMUs aiming to improve system reliability.•Only two uPMUs are needed to achieve an acceptable resolution in fault location.•A mathematical formulation to quantify the improvement in the system reliability.•Genetic algorithm and variable neighborhood search solve the uPMU allocation.•Statistical analysis for assessing the performance of the used metaheuristic.
Due to the dynamic nature of modern distribution systems, the deployment of micro-phasor measurement units (uPMU) is becoming increasingly common among utilities to improve system monitoring and reliability. However, given their high investment costs, deploying a large number of these devices becomes unfeasible. Hence, unlike other approaches found in the literature that focus on observability criteria, this work presents an algorithm for optimal placement of uPMUs aimed at improving distribution system reliability. The algorithm defines the optimal number and location of the uPMUs through an objective function based on the resolution of a fault location technique that works in conjunction with pseudo-measurements to successfully locate a contingency. The meta-heuristics Genetic Algorithm and Reduced Variable Neighborhood Search are employed to address this problem. The proposed method has been validated on a three-phase 39-bus distribution system and a real distribution feeder with 962 buses from an Ecuadorian electric distribution utility. The results obtained confirm the effectiveness of the method, as with the deployment of only two uPMUs, the energy not supplied decreases by 13.84 % and 24.96 % for the 39-bus and 962-bus systems, respectively. Moreover, in the 962-bus system, the System Average Interruption Duration Index (SAIDI) is reduced by 20.36 %. |
---|---|
ISSN: | 0378-7796 |
DOI: | 10.1016/j.epsr.2024.110910 |