Dynamic punching shear of impacting RC flat slabs with drop panels
•RC flat slabs design aims at preventing punching shear under static loading.•A failed slab impacts with the slab below and leads to progressive collapse.•Drop panels may improve the slabs impact, controlling local thickness impact area.•Drop panels may improve the impact performance and even preven...
Gespeichert in:
Veröffentlicht in: | Engineering failure analysis 2021-11, Vol.129, p.105682, Article 105682 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | •RC flat slabs design aims at preventing punching shear under static loading.•A failed slab impacts with the slab below and leads to progressive collapse.•Drop panels may improve the slabs impact, controlling local thickness impact area.•Drop panels may improve the impact performance and even prevent failure.•There are optimal drop panel dimensions yielding best performance.•Larger or smaller drop panels may yield large damage and even slab failure.
Reinforced concrete flat slabs (FS) are sensitive to punching shear failure. Such failure may progress to the slab loss of supports and its downwards motion that is followed by its impact with the slab underneath. This slabs impact may initiate a progressive collapse of the entire building. The design guidelines provided by modern standards to avoid punching shear failure and to prevent post-punching loss of slab support in an attempt to prevent progressive collapse are based on static loads considerations and tests and do not include considerations and guidelines that are needed to guarantee resistance to impact loading. In our studies on the impact response of impacting slabs we learnt that increasing the slab thickness and the amount of reinforcement do not improve the slabs resistance to impact and cannot prevent the severe resulting damage. Drop panels are a common means to enhance the static resistance of slabs against punching shear as they increase the slab thickness around the column, where highest shear stresses are developed. The present paper aims at the investigation of the impact response of flat slabs with drop panels and examine their added contribution to reduce the post-impact damage and achieve a stable state of the impacted slab, thus preventing a following progressive collapse scenario. In addition to the local slab depth increase, the drop panel also limits the contact zone of the impacting slabs. Both aspects positively contribute to reducing the impact induced damage. The drop panel provides a means to locally increase the slab resistance without considerably increasing its mass, thus controlling the impact load intensity while increasing the slab’s resistance. The paper investigates the impacts of different possible combinations of two adjacent slabs with/without drop panels and finds that while flat slabs without drop panels fail upon impact, slabs with drop panels may survive the impact and avoid the following progressive collapse scenario. Opposed to static design where a drop panel |
---|---|
ISSN: | 1350-6307 1873-1961 |
DOI: | 10.1016/j.engfailanal.2021.105682 |