Shear behavior of reinforced concrete beams repaired using a hybrid scheme with stainless steel rebars and CFRP sheets

•Stainless steel rebar and CFRP sheet were used to repair corroded RC beam.•Effect of rebar types and CFRP sheet wrapping schemes on the shear behaviour of RC beams was investigated experimentally.•Cutting the bottom arm of corroded stirrup significantly affects the maximum load of the shear-critica...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Construction & building materials 2023-01, Vol.363, p.129817, Article 129817
Hauptverfasser: Hasan, Md Abul, Akiyama, Mitsuyoshi, Kojima, Keisuke, Izumi, Naoki
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•Stainless steel rebar and CFRP sheet were used to repair corroded RC beam.•Effect of rebar types and CFRP sheet wrapping schemes on the shear behaviour of RC beams was investigated experimentally.•Cutting the bottom arm of corroded stirrup significantly affects the maximum load of the shear-critical RC beam.•Complete wrapping of CFRP sheets is adequate to overcome the shear deficiency due to cutting the bottom arm of corroded stirrup for overlaying retrofitting purposes.•Proposed design equation can predict the shear contribution from deficient stirrups of the repaired beam accurately. Repairing corroded flexural-deficient reinforced concrete (RC) structures using a hybrid scheme with stainless steel (SS) rebars and carbon-fiber-reinforced polymer (CFRP) sheets revealed excellent structural performance and contributes to lower maintenance costs in the remaining service life of the repaired structure. However, although cutting the bottom arm of stirrups in a hybrid repair method could affect the structural performance of shear-critical RC beams since this effect was not investigated in the past research. In this paper, structural performance of a group of shear-deficient RC beams repaired using the hybrid method is investigated experimentally to examine the effect of cutting the bottom arm of stirrup on the shear capacity of the repaired beams. The test variables included the longitudinal reinforcement types (i.e. carbon and SS), shear reinforcement configurations, and CFRP sheet wrapping schemes. Experimental results demonstrate that cutting the bottom arm of stirrup for replacing the corroded tensile rebar could significantly reduce the shear capacity of the retrofitted beams. Therefore, strengthening using CFRP sheet is needed to restore the shear performance of the retrofitted beams. Test results revealed that complete wrapping of CFRP sheet is effective to overcome the shear deficiency due to cutting the bottom arm of stirrup in the shear-critical RC beams. In addition, the effectiveness of CFRP sheet wrapping schemes on shear performance of SS-RC beams is approximately identical with that of CS-RC beams. Finally, a design methodology to repair the corroded RC bridge using hybrid method is developed and presented based on bending and shear tests.
ISSN:0950-0618
1879-0526