Label-free immunosensor for detection of hepatitis C (HCV) core antigen using ternary polypyrrole-Ag doped ZnO-exfoliated graphene nanocomposite

A label-free immunosensor for detection of hepatitis C (HCV) core antigen was fabricated using a ternary nanocomposite based on polypyrrole (PPy), silver doped zinc oxide (Ag-ZnO) and exfoliated graphene (Ex-Gr). The negatively charged anticore mAbs 19D9D6 (1 NLB monoclonal antibodies) were immobili...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Colloids and surfaces. A, Physicochemical and engineering aspects Physicochemical and engineering aspects, 2024-01, Vol.681, p.132709, Article 132709
Hauptverfasser: Zia, Tanveer ul Haq, Ali Shah, Anwar ul Haq, Ara, Behisht, Gul, Kashif
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A label-free immunosensor for detection of hepatitis C (HCV) core antigen was fabricated using a ternary nanocomposite based on polypyrrole (PPy), silver doped zinc oxide (Ag-ZnO) and exfoliated graphene (Ex-Gr). The negatively charged anticore mAbs 19D9D6 (1 NLB monoclonal antibodies) were immobilized at the PPy/Ag-ZnO/Ex-Gr 9 % nanocomposite surface as it is suitable for non-covalent (electrostatic) immobilization for fabricating the label-free immunosensor. The isoelectric point (IEP) achieved at around pH 7 for PPy shifts to the lower value of pH 5.75 for PPy/Ag-ZnO/Ex-Gr 9 % nanocomposite. The linear sweep voltammetric (LSV) analysis of the as-prepared samples indicate high electrochemical activity. Similarly, electrochemical impedance spectroscopy (EIS) and cyclic voltammetry confirmed the hindrance in the faradaic processes due to the presence of the interfacial biomolecules layer, after surface modification confirming the fabrication of the immunosensor. The LSV current signal response decrement for the concentration range of antigen [HCV core nucleocapsid polypeptide (residues 13–40) (RNTNRRPQ DVKFPGGGQI VGGVYLLPRR)] ranging from 0.001 ng mL-1 to 200 ng mL-1 was performed depicting the hindrance to electron transfer increases with increase in the antigen concentration as antigen antibody interaction takes place thickening the insulative layer of biomolecules at the interface leading to gradual decrease in the current response. The limit of detection was measured to be approximately 0.41 pg mL-1, respectively (S/N = 3). The single interfering protein doesn’t decrease the LSV current response for HCV (50 ng mL-1) depicting the immunospecificity i-e selectivity of the fabricated immunosensor. The as prepared label-free immunosensor displayed lower limit of detection, high selectivity and stability. [Display omitted] •Ternary nanocomposite based on polypyrrole, silver doped zinc oxide and exfoliated graphene was prepared.•mAbs 19D9D6 (1 NLB monoclonal antibodies) were non-covalently immobilized at surface of as prepared ternary nanocomposite.•The antigen interaction takes place antibody at the surface of the biocompatible platform.•The electron transfer hindrance at the interface was depicted as decrement in the LSV current signal response.•The limit of detection was measured to be approximately 0.41 pg mL-1, respectively (S/N = 3).
ISSN:0927-7757
1873-4359
DOI:10.1016/j.colsurfa.2023.132709