Nasal air conditioning following total inferior turbinectomy compared to inferior turbinoplasty – A computational fluid dynamics study

The aim of this study was to use computational fluid dynamics (CFD) to investigate the effects on nasal heat exchange and humidification of two different surgical techniques for reducing the inferior turbinate under different environmental conditions. Virtual surgery using two techniques of turbinat...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical biomechanics (Bristol) 2021-01, Vol.81, p.105237, Article 105237
Hauptverfasser: Siu, Joey, Inthavong, Kiao, Dong, Jingliang, Shang, Yidan, Douglas, Richard George
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The aim of this study was to use computational fluid dynamics (CFD) to investigate the effects on nasal heat exchange and humidification of two different surgical techniques for reducing the inferior turbinate under different environmental conditions. Virtual surgery using two techniques of turbinate reduction was performed in eight nasal airway obstruction patients. Bilateral nasal airway models for each patient were compared: 1) Pre-operative 2) Post inferior turbinoplasty 3) Post total inferior turbinate resection (ITR). Two representative healthy models were included. Three different environmental conditions were investigated 1) ambient air 2) cold, dry air 3) hot, humid air. CFD modelling of airflow and conditioning was performed under steady-state, laminar, inspiratory conditions. Nasal conditioning is significantly altered following inferior turbinate reduction surgery, particularly with ITR under cold, dry inspired air (CDA). The degree of impairment is minor under the simulated range of environmental conditions (temperature = 12–40 °C; relative humidity = 13–80%). Streams of significantly colder air are found in the nasopharynx and more prevalent under CDA in ITR. These are related to high velocity flow streams, which remain cool in their centre throughout the widened inferior nasal cavity. Reduced air-mucosal heat exchange and moisture carrying capacity occurs under cooler temperatures in patients following inferior turbinate surgery. The clinical impact in extremely cold and dry conditions in groups with poor baseline respiratory function, respiratory illness, or endurance athletes is of special interest. •Two techniques for inferior turbinate reduction are compared in this CFD study.•Reduced air-mucosal heat and water exchange occurs with cold, dry inspired air.•The degree of impairment is accentuated with total turbinate resection (ITR).•Streams of much colder air are found in the nasopharynx following ITR.•Further study in the clinical impact on respiratory illness is of special interest.
ISSN:0268-0033
1879-1271
DOI:10.1016/j.clinbiomech.2020.105237