Coupling cation and anion exchange chromatography for fast separation of monoclonal antibody charge variants
•CEX and AEX were coupled to separate monoclonal antibody (mAb) variants.•In CEX basic variant was isolated, in AEX acidic and main variants were separated.•Mathematical model was used for optimizing the coupled process.•Optimal column coupling and mAb load depended on variant composition.•Optimized...
Gespeichert in:
Veröffentlicht in: | Journal of Chromatography A 2024-09, Vol.1733, p.465256, Article 465256 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | •CEX and AEX were coupled to separate monoclonal antibody (mAb) variants.•In CEX basic variant was isolated, in AEX acidic and main variants were separated.•Mathematical model was used for optimizing the coupled process.•Optimal column coupling and mAb load depended on variant composition.•Optimized loading density was maximum 26 mg ml−1 for CEX, 600 mg ml−1 for AEX.
A design procedure for the separation of charge variants of a monoclonal antibody (mAb) was developed, which was based on the coupling of cation-exchange chromatography (CEX) and anion-exchange chromatography (AEX) under high loading conditions. The design of the coupled process was supported by a dynamic model. The model was calibrated on the basis of band profiles of variants determined experimentally for the mAb materials of different variant compositions. The numerical simulations were used to select the coupling configuration and the loading conditions that allowed for efficient separation of the mAb materials into three products enriched with each individual variant: the acidic (av), main (mv) and basic (bv) one. In the CEX section, a two-step pH gradient was used to split the loaded mass of mAb into a weakly bound fraction enriched with av and mv, and a strongly bound fraction containing the bv-rich product. The weakly bound fraction was further processed in the AEX section, where the mv-rich product was eluted in flowthrough, while the av-rich product was collected by a step change in pH. The choice of flow distribution and the number of columns in the CEX and AEX sections depended on the variant composition of the mAb material. For the selected configurations, the optimized mAb loading density in the CEX columns ranged from 10 to 26 mg mL-1, while in the AEX columns it was as high as 300 or 600 mg mL-1, depending on the variant composition of the mAb material. By proper selection of the loading condition, a trade-off between yield and purity of the products could be reached. |
---|---|
ISSN: | 0021-9673 1873-3778 |
DOI: | 10.1016/j.chroma.2024.465256 |