Combination of nZVI and DC for the in-situ remediation of chlorinated ethenes: An environmental and economic case study

Over the past two decades, the use of nanoscale zero-valent iron (nZVI) has emerged as a standard method of contaminated groundwater remediation. The effectiveness of this method depends on key intrinsic hydrogeological parameters, which can affect both reactivity of the nanoparticles and their migr...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Chemosphere (Oxford) 2020-04, Vol.245, p.125576, Article 125576
Hauptverfasser: Černíková, Martina, Nosek, Jaroslav, Černík, Miroslav
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Over the past two decades, the use of nanoscale zero-valent iron (nZVI) has emerged as a standard method of contaminated groundwater remediation. The effectiveness of this method depends on key intrinsic hydrogeological parameters, which can affect both reactivity of the nanoparticles and their migration in the aquifer. In the case of low hydraulic permeability, the migration of nanoparticles is limited, which negatively influences remediation. An application of nZVI reinforced with a DC electric field led to a significant increase in the efficiency of remediation, as demonstrated by long-term monitoring at a former industrial site in Horice (Czech Republic). For the method testing, a 12 × 9 m polygon was defined around well IS4, where the original contamination was predominantly composed of DCE (7300 μg/l), and with a total concentration of chlorinated ethenes of 8880 μg/l. During the first stage of the activities, 49 kg of nZVI was injected and monitored for two years. Subsequently, the electrodes were installed, and for three years, the synergistic action of nZVI within an applied DC field was monitored. Based on 32 monitoring campaigns performed over the six years, the combined method was compared with an application of the only nZVI in technical, environmental and economic terms. Technically, the method requires annual reinstallation of anodes as a result of their oxidative disintegration. Environmentally, the method provides significantly improved chlorinated ethane reduction, remediation of low permeable zones, and extended efficiency. Economically, the method is five times cheaper when compared to the nZVI used alone. [Display omitted] •Use of nZVI in the combination with direct current for in situ remediation.•Comparing of nZVI and nZVI with direct current.•Environmental and economical case study for chlorinated ethenes.•Long-term run pilot test on real contaminated site.•Assess ecological and economic effects.
ISSN:0045-6535
1879-1298
DOI:10.1016/j.chemosphere.2019.125576