In situ S isotopic analysis in apatite using laser ablation-multiple collector-inductively coupled plasma mass spectrometry

The S isotope composition (34S/32S) in apatite has been considered as a new powerful tool to trace S source reservoirs and to evaluate redox state and dynamic sulfur behavior in magmatic systems. This study presents the first in situ method to analyze S isotope compositions in apatite using laser ab...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Chemical geology 2023-10, Vol.636, p.121651, Article 121651
Hauptverfasser: Li, Qinglin, Zhang, Wen, Hu, Zhaochu, Feng, Yantong, Hu, Hao, Luo, Tao, Huang, Jing, Zeng, Xianli
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The S isotope composition (34S/32S) in apatite has been considered as a new powerful tool to trace S source reservoirs and to evaluate redox state and dynamic sulfur behavior in magmatic systems. This study presents the first in situ method to analyze S isotope compositions in apatite using laser ablation multiple collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS). The sulfur isotope analysis of low-S apatite suffered the problem of high background interference, resulting in a low ratio of signal to noise (S/N). A detailed investigation found that ∼50% background of S isotopes originated from memory effect in the aerosol particles transformation system and can be removed through careful cleaning or replacement. A linear regression calculation method was proposed instead of the traditional data reduction method to improve the performance of correcting the S background signal. Femtosecond laser ablation system (fs-LA) was used to reduce the thermal effect and suppress the potential fractionation of S isotopes during the laser ablation process, significantly improving the stability of δ34SV-CDT values at different laser ablation parameters. Seven natural apatite samples with a large S concentration range were measured by the presented method. A good agreement of δ34SV-CDT values between fs-LA-MC-ICP-MS and IR-MS was obtained. The reproducibility of δ34SV-CDT obtained from fs-LA-MC-ICP-MS was similar to that in SIMS. These results confirm that the presented method can provide high-quality S isotopic compositions in natural apatites. Four apatite samples (Sly-1, Sly-2, MG, and OL-1) with various concentrations of SO3 (0.21% to 1.26%) show the homogeneous S isotope compositions based on the large amounts of repeated analyses using fs-LA-MC-ICP-MS. They are suggested as the high-quality external reference materials for in situ S isotope analysis for LA-MC-ICP-MS and SIMS. •δ34SV-CDT in apatite is determined by fs-LA-MC-ICP-MS.•The analytical precision is comparable to that in SIMS for the low-S apatites (0.2% to 1.2%).•Four apatites are recommended as potential standards for S isotope micro-analysis.
ISSN:0009-2541
1872-6836
DOI:10.1016/j.chemgeo.2023.121651