A flexible and multimodal biosensing patch integrated with microfluidics for chronic wound monitoring
•Introduce a flexible multi-biosensing patch for the wound status at the point of care.•Developed bioinspired microfluidic wound exudate collector with a sensor array.•V-shaped posts with fluidic channels enable unidirectional exudate transfer.•Gold nanowire-reduced graphene oxide composite enhances...
Gespeichert in:
Veröffentlicht in: | Chemical engineering journal (Lausanne, Switzerland : 1996) Switzerland : 1996), 2024-12, Vol.501, p.157673, Article 157673 |
---|---|
Hauptverfasser: | , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | •Introduce a flexible multi-biosensing patch for the wound status at the point of care.•Developed bioinspired microfluidic wound exudate collector with a sensor array.•V-shaped posts with fluidic channels enable unidirectional exudate transfer.•Gold nanowire-reduced graphene oxide composite enhances electrochemical sensing.•Sensor's response corrected with pH and T compensation for improved accuracy.
A wearable biosensing patch for the monitoring of physiochemical parameters related to chronic wounds presents a promising approach to personalized wound management. Despite considerable advances in multimodal biosensing patches for wound care, fully integrated patches with microfluidic channels to monitor multiple parameters simultaneously are still a challenge. Herein, a flexible multimodal biosensing patch integrated with microfluidic channels is newly proposed. The patch comprises a polar array of seven biosensors fabricated on a flexible polyethylene terephthalate substrate. An SU-8-based microfluidic channel with arrowhead micropatterns is formed directly on the sensor via the lithography process. The integration of the microfluidic channels results in a fluid collection efficiency that is increased 6.5 times higher owing to the fluidic diode effect of the micropattern. The sensing platform is functionalized with a gold nanowire-incorporated reduced graphene oxide composite to fabricate an electrochemical biosensor array. This array is used in detecting three metabolites (glucose, lactate, and uric acid), two ions (Na+ andK+), pH, and temperature. The sensor responses are calibrated using a pH- and temperature-compensation algorithm to accurately quantify the analyte concentration and evaluate multi-sensing capability in the rat wound model. Its unique design and multiplexed sensing capacities offer significant advancements in nonhealing wound monitoring. |
---|---|
ISSN: | 1385-8947 |
DOI: | 10.1016/j.cej.2024.157673 |