Nanofiber-based colorimetric platform for point-of-care detection of E. coli

[Display omitted] •A nanofiber-based colorimetric platform for E. coli detection was prepared.•This platform can realize chromogenic and fluorescent dual-channel colorimetric detection.•This platform has high sensitivity to E. coli and well anti-ionic and anti-pH interference.•Nanofiber-based platfo...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Chemical engineering journal (Lausanne, Switzerland : 1996) Switzerland : 1996), 2023-05, Vol.463, p.142357, Article 142357
Hauptverfasser: Zhang, Jiaqi, Hurren, Christopher, Lu, Zhentan, Wang, Dong
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:[Display omitted] •A nanofiber-based colorimetric platform for E. coli detection was prepared.•This platform can realize chromogenic and fluorescent dual-channel colorimetric detection.•This platform has high sensitivity to E. coli and well anti-ionic and anti-pH interference.•Nanofiber-based platform are portable and widely used for point-of-care detection.•Smartphone analysis can realize rapid qualitative and quantitative detection of E. coli. Accurate and rapid detection of bacteria in complex environmental samples using simple and portable devices is still a major challenge. This research presents a simple nanofiber-based platform for highly sensitive colorimetric/fluorometric detection of Escherichia coli (E. coli). Nanofiber membranes (NFM) were loaded with target molecules (fluorescent and chromogenic substrate) via chemical modification to prepare functional NFM (NFM-MUG and NFM-XG). The β-glucuronidase secreted by E. coli during the metabolic process triggered the functionalized NFM to produce biological signals and color change. The intensity of bio-signals and color was shown to enable quantitative and qualitative detection of E. coli. The nanofiber-based platforms exhibited high stability and a wide detection range (102-107 CFU/mL). The limit of detection (LOD) of NFM-MUG and NFM-XG sensors for E. coli were 26 and 69 CFU mL−1, respectively. The sensing time required for NFM-MUG and NFM-XG was 15 mins and 30 mins respectively. The nanofiber-based platforms also exhibited high specificity and low interference from ionic compounds and pH changes. Notably, this assay was easily combined with a smartphone app as a portable device for on-site detection of E. coli, showing a great promise in the field of environmental and food safety testing.
ISSN:1385-8947
1873-3212
DOI:10.1016/j.cej.2023.142357