Heparin coating on 3D printed poly (l-lactic acid) biodegradable cardiovascular stent via mild surface modification approach for coronary artery implantation
[Display omitted] •Biodegradable polymeric stent was successfully prepared using 3D printing system.•Heparinization enhances biocompatibility and anti-coagulation activity.•Developed 3D stent showed excellent property in vitro and in vivo. In the last decade, stent implantation therapy has been wide...
Gespeichert in:
Veröffentlicht in: | Chemical engineering journal (Lausanne, Switzerland : 1996) Switzerland : 1996), 2019-12, Vol.378, p.122116, Article 122116 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | [Display omitted]
•Biodegradable polymeric stent was successfully prepared using 3D printing system.•Heparinization enhances biocompatibility and anti-coagulation activity.•Developed 3D stent showed excellent property in vitro and in vivo.
In the last decade, stent implantation therapy has been widely performed in the clinic. Although the patient's cardiovascular state depends on their age, gender, and health condition, the development of customized individual stents has been limited. Thus, a patient-specific stent manufacturing system should be devised for more successful stent therapy. In this study, we prepared a 3D printed PLA biodegradable polymeric stent using polydopamine (PDA), polyethyleneimine (PEI) and heparin (Hep) chemistry to prevent restenosis and thrombosis with anticoagulation and good blood compatibility. Physico-chemical characterization indicated that pristine PLA substrates were well modified as the amine abundant surface allowed for coating of a large amount of Hep. From in vitro and ex vivo analysis, heparinized 3D PLA stents showed excellent thromboresistance and hemocompatibility functions as well as modulation of smooth muscle cell (SMC) and endothelial cell (EC) proliferation. In an in vivo study, the heparinized 3D PLA stent showed the widest lumen area with the least neointimal hyperplasia and without atherosclerosis or thrombosis. All of these assessments clearly confirmed that our innovative strategy may suggest a useful paradigm as a preparation method for a patient-customized fully biodegradable individual stent for successful implantation therapy. This would find wide utilization for cardiovascular clinical applications. |
---|---|
ISSN: | 1385-8947 1873-3212 |
DOI: | 10.1016/j.cej.2019.122116 |