Investigation of a DNA tagged aerosol tracer method for In Situ evaluation of germicidal UV air cleaner effectiveness

Transmission of respiratory pathogens occurs primarily in indoor settings, interventions to reduce the risk of their transmission include increases in outdoor air introduction, filtration, and ultraviolet germicidal irradiation (UVGI). However, validating these interventions is challenging, particul...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Building and environment 2024-08, Vol.262, p.111828, Article 111828
Hauptverfasser: Arvelo, Ilan, Blatchley, Ernest R., Bahnfleth, William P., Arnold, Phil, Fry, Ashley, Topete, Maria, Zhou, Ling, Palmer, William, Piper, Patrick J., Zhang, Jianping, Dexter, W. Andrew, Palma, Nilson, Heredia, Nicholas J.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Transmission of respiratory pathogens occurs primarily in indoor settings, interventions to reduce the risk of their transmission include increases in outdoor air introduction, filtration, and ultraviolet germicidal irradiation (UVGI). However, validating these interventions is challenging, particularly in actual applications. This study introduces an aerosol tracer system utilizing DNA as tracer molecule, aimed at quantitative characterization of the performance of indoor air cleaning systems. Two DNA tracers, designed one to be relatively UV-resistant and another relatively UV-sensitive, were employed to assess air quality changes related to filtration and ventilation and the contributions of UVGI fixtures in various built environments. We conducted controlled UV exposure experiments of DNA-tagged tracers on foil coupons, aerosolization studies in a test chamber, and in a commercial building conference room. The DNA tracer results provided insights at the point of sampling into the effects of complex airflow dynamics. Additionally, a way to scale the DNA tracer results to MS2 bacteriophage is proposed. Four distinct UV devices challenged with MS2 in a chamber test produced equivalent clean airflow rates of 13–147 CFM. Scaled equivalent clean airflow rates in a commercial building setting using the UV-sensitive tracer varied from 47 percent less to 101 percent more than the chamber results, possibly due to differences in airflow patterns, equipment configuration, and other factors. Our findings provide quantitative understanding of the interaction between UV-sensitive aerosols and the built environment, with implications for environmental monitoring, measuring UVGI fixture impact in field settings, and addressing current technologies limitations for assessing UVGI disinfection efficacy. [Display omitted] •UV surface inactivation of synthetic DNA sequences at 222, 254, and 282 nm.•Novel DNA-tagged aerosols sensitive to UV as a surrogate for viral inactivation.•New proposed method allows for UV air disinfection measurement in occupied spaces.•Equivalent clean air delivery rate estimation applying DNA-tagged aerosols.•In Situ evaluation of UV air disinfection differs from expected chamber results.