Correlations for forced convective heat transfer coefficients at the windward building façade with vertical louvers
Vertical louvers are a widely used external shading system to control natural lighting and solar heat gain for buildings. However, when installed on a building façade, they can disrupt the flow field around the façade and affect the external convective heat transfer process of building's exteri...
Gespeichert in:
Veröffentlicht in: | Building and environment 2023-08, Vol.242, p.110611, Article 110611 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Vertical louvers are a widely used external shading system to control natural lighting and solar heat gain for buildings. However, when installed on a building façade, they can disrupt the flow field around the façade and affect the external convective heat transfer process of building's exterior surfaces. To this end, this paper conducted CFD simulations to clarify the forced convective heat transfer patterns in a vertical louver-facade system based on the k-ω SST model with a detailed verification. The extended Newton's cooling equation is used to describe the heat exchange process between louvers, building façade, and air, which generates four heat transfer coefficients: hwa, hwb, hba, and hbw. Then the impacts of dimensionless temperature difference (θ), louver angle (φ), louver slat width (B), and installation distance (W) on the heat transfer coefficients are investigated. The results show that θ does not affect the average heat transfer coefficients. hwa reaches a minimum value and hba reaches a maximum value when φ = 75o. In addition, hwa increases by 55.3% and hba decreases by 21.9% as B increases from 0.3 m to 1 m. When W increases from 0.25 m to 1 m, hwa decreases by 5.6% and hba increases by 39.6%. The variation in the heat transfer coefficients (hwb and hbw) between the louvers and building façade is also explained. Finally, new correlations of paired heat transfer coefficients are established as a function of φ, B, W, and wind velocity (U10). The accuracy of these correlations is evaluated by comparing calculated values with simulated results.
•Impact of vertical louvers on convective heat transfer at façades is investigated.•Using the extended Newton's cooling equation to describe the heat exchange process.•Taking into account the effects of louver geometry and temperature differences.•Paired CHTC correlations for windward building facades and louver surfaces.•Accuracy evaluation for CHTC correlations. |
---|---|
ISSN: | 0360-1323 1873-684X |
DOI: | 10.1016/j.buildenv.2023.110611 |