Estimation of spectral components of auditory steady-state response using least squares and phase compensation for objective response detectors
•Auditory Steady-State Response can be used to estimate hearing thresholds.•Objective Response Detectors are statistical tools used to detect ASSR.•The discrete Fourier transform is usually used to estimate spectral component of ASSR.•The method of least square with phase compensation can bypass the...
Gespeichert in:
Veröffentlicht in: | Biomedical signal processing and control 2023-03, Vol.81, p.104413, Article 104413 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | •Auditory Steady-State Response can be used to estimate hearing thresholds.•Objective Response Detectors are statistical tools used to detect ASSR.•The discrete Fourier transform is usually used to estimate spectral component of ASSR.•The method of least square with phase compensation can bypass the coherent sampling criterion.
Auditory Steady-State Responses (ASSR) are evoked potentials useful for estimating hearing thresholds. The ASSR are manifested in the electroencephalogram (EEG) and their presence is verified by statistical methods, usually in the frequency domain, with techniques called Objective Response Detectors (ORD). The standard method of implementing ORD involves dividing the EEG signal into epochs and estimating the spectral components of each epoch at the frequencies of stimulation using the discrete Fourier transform (DFT). One of the disadvantages of estimating spectral components by DFT is that it is necessary to respect the coherent sampling criterion, which reduces considerably the possible choices of epoch length and frequencies of stimulation to apply ORD techniques. This work proposes the least squares method with phase compensation as an alternative technique to DFT. In this work, the ORD technique used was the magnitude-squared coherence (MSC). Our results showed that the highest detection rates occurred slightly above the frequencies of stimulation, which indicates a small calibration error in the dataset. The second analysis was to verify how the performance of the MSC behaves when varying the epoch length. This analysis allowed us to verify that, in real data, the performance of the MSC worsens when using either very small or very large epoch lengths. Thus, in conclusion, the method proposed in this work allowed performing analysis with an ORD technique varying the epoch length and the analyzed frequencies, which was not possible using the DFT. |
---|---|
ISSN: | 1746-8094 1746-8108 |
DOI: | 10.1016/j.bspc.2022.104413 |