Tailoring of bimetallic organic framework-polymeric film composites: Real-time fouling-free electrocatalytic application of hydrogen sulfide releasing from organic donors and live cells
Real-time fouling-free electrocatalytic application of H2S in organic donors and live cells based on bimetallic Ni-Co-MOF with PEDOTs film composite. [Display omitted] •Fouling-free and selective H2S was developed based on Ni-Co-MOF with PEDOTs film.•Dynamic real-time monitoring of H2S was achieved...
Gespeichert in:
Veröffentlicht in: | Applied surface science 2023-03, Vol.613, p.156141, Article 156141 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Real-time fouling-free electrocatalytic application of H2S in organic donors and live cells based on bimetallic Ni-Co-MOF with PEDOTs film composite.
[Display omitted]
•Fouling-free and selective H2S was developed based on Ni-Co-MOF with PEDOTs film.•Dynamic real-time monitoring of H2S was achieved in GYY4137 and organic donors.•Sensor showed wide linear-range concentration of 1 nM to 250 µM and LOD of 0.186 nM.•Practical application was demonstrated in human whole blood and biofluid samples.•Real-time endogenous release of H2S was monitored in live E. coli MG1655 cells.
Electrochemical real-time hydrogen sulfide (H2S) sensor in biological and chemical environments are great interest due to their impact of interferences and electrode-fouling effects. Hence, fouling-free detection of H2S is a key challenging to explore an unmasked electrocatalytic activity. In this context, a simple and robust strategy was developed based on bimetallic Ni-Co-MOF with poly(3,4-ethylenedioxythiophene) (PEDOTs) and poly(o-phenylenediamine) (PoPDA). The hybrid composite system exhibits tunable-structural morphology, cohesive electrical conductivity, strong interfacial chemical bonding and good anti-fouling property. The PEDOTs@Ni-Co-MOF/GCE yielded an enhanced catalytic performance with a concentration range of 1 nM to 250 µM, low detection limit of 0.186 nM, and high sensitivity (7.29 μA μM−1 cm−2). The water soluble GYY4137, and phosphordithioates-based donors were achieved dynamically quantify the real-time release of H2S against pH and co-incubation time (0–30 min). Additionally, bimetallic-MOF with the polymeric film platform achieved highly selective in other sulfur-containing complex medium and biomolecules due to its strong electrostatic net-charges and size exclusivity. A practical application was demonstrated in whole blood and biofluids with acceptable recoveries from 97.40 to 98.79 % (n = 3). The real-time endogenous release of H2S was evaluated in live cells (E. coli MG1655) by using a cysteine stimulator. |
---|---|
ISSN: | 0169-4332 1873-5584 |
DOI: | 10.1016/j.apsusc.2022.156141 |