Inelastic background modelling applied to hard X-ray photoelectron spectroscopy of deeply buried layers: A comparison of synchrotron and lab-based (9.25 keV) measurements
[Display omitted] •Hard X-ray photoelectron spectroscopy can probe deeply buried layers.•We compare a new laboratory instrument to synchrotron measurements.•Inelastic background modelling further extends the sampling depth.•Adjusted sampling from bulk towards surface using angle-resolved HAXPES.•We...
Gespeichert in:
Veröffentlicht in: | Applied surface science 2021-03, Vol.541, p.148635, Article 148635 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | [Display omitted]
•Hard X-ray photoelectron spectroscopy can probe deeply buried layers.•We compare a new laboratory instrument to synchrotron measurements.•Inelastic background modelling further extends the sampling depth.•Adjusted sampling from bulk towards surface using angle-resolved HAXPES.•We demonstrate quantification is possible using high energy photons.
Hard X-ray Photoelectron Spectroscopy (HAXPES) provides minimally destructive depth profiling into the bulk, extending the photoelectron sampling depth. Detection of deeply buried layers beyond the elastic limit is enabled through inelastic background analysis. To test the robustness of this technique, we present results on a thin (18 nm) layer of metal–organic complex buried up to 200 nm beneath organic material. Overlayers with thicknesses 25–140 nm were measured using photon energies ranging 6–10 keV at the I09 end station at Diamond Light Source, and a new fixed energy Ga Kα (9.25 keV) laboratory-based HAXPES spectrometer was also used to measure samples with overlayers up to 200 nm thick. The sampling depth was varied: at Diamond Light Source by changing the photon energy, and in the lab system by performing angle-resolved measurements. For all the different overlayers and sampling depths, inelastic background modelling consistently provided thicknesses which agreed, within reasonable error, with the ellipsometric thickness. Relative sensitivity factors were calculated, and these factors consistently provided reasonable agreement with the expected nominal stoichiometry, suggesting the calculation method can be extended to any element. These results demonstrate the potential for the characterisation of deeply buried layers using synchrotron and laboratory-based HAXPES. |
---|---|
ISSN: | 0169-4332 1873-5584 |
DOI: | 10.1016/j.apsusc.2020.148635 |