Thermodynamic optimisation of a booster-ejector vapour compression refrigeration system using solar energy and R152a/Cu nano-refrigerant

•Solar-driven EEVCRS with R152a/Cu was proposed for the first time.•Thermodynamic optimization and analysis of proposed system were carried out.•COP and exergy efficiency rose by a maximum of 14.05%.•Total exergy destruction reduced by a maximum of 34.48%.•Solar panel area reduced by a maximum 14.27...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied thermal engineering 2023-07, Vol.229, p.120553, Article 120553
Hauptverfasser: Aktemur, Cenker, Tekin Ozturk, İlhan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•Solar-driven EEVCRS with R152a/Cu was proposed for the first time.•Thermodynamic optimization and analysis of proposed system were carried out.•COP and exergy efficiency rose by a maximum of 14.05%.•Total exergy destruction reduced by a maximum of 34.48%.•Solar panel area reduced by a maximum 14.27%. Conventional vapour compression refrigeration systems require high electrical energy for low temperature applications. For the first time in the literature to reduce this required energy, comprehensive thermodynamic analysis and optimization of booster-assisted ejector expansion vapour compression refrigeration system with R152a/Cu nano-refrigerant are presented for low-temperature applications. Solar panels are used to cover the total compressor work, using the climate data of Izmir, Turkey. According to the thermodynamic optimization findings, the use of nanoparticles in the refrigeration system led to several improvements when compared to the R152a refrigeration system. These enhancements include a reduction of 6.52-11.71% in the main compressor discharge temperature, a decrease of 18.46-34.48% in the total exergy destruction rate, an increase of 3.08-4.04% in the entrainment ratio, a reduction of 0.089-3.25% in the ejector area ratio, a decrease of 8.34-14.27% in the panel area, and an increase of 8.09-14.05% in both the coefficient of performance and exergy efficiency. Another thing worth mentioning is that coefficient of performance and exergy efficiency improved by 2.06% and 1.96%, respectively, while total exergy destruction reduced by 4.83% compared to our previous study. The results obtained from the thermodynamic optimisation provide a useful reference for the design of an experimental system, as they provide evidence of model validity and can guide the implementation of the system.
ISSN:1359-4311