Interrelationship between flow profiles and the magnetic waveform and their influence on the performance of first-order active magnetic regenerators

Magnetic refrigeration is one of the most prominent unconventional near-room-temperature cooling technologies. However, some factors currently prevent it from reaching commercial levels, such as the high cost and relatively low energetic performance of magnetic materials used in the Active Magnetic...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied thermal engineering 2023-01, Vol.219, p.119581, Article 119581
Hauptverfasser: Vieira, Bernardo P., Bez, Henrique Neves, dos Santos, Diego, Lozano, Jaime A., Barbosa, Jader R.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Magnetic refrigeration is one of the most prominent unconventional near-room-temperature cooling technologies. However, some factors currently prevent it from reaching commercial levels, such as the high cost and relatively low energetic performance of magnetic materials used in the Active Magnetic Regenerator (AMR) and Magnetic Circuit (MC). As a result, an essential task in designing such systems is to extract the best possible performance by finding an optimal operating condition. In this paper, an experimentally validated one-dimensional two-temperature AMR model analyses the relationship between the time-dependent flow and magnetic field waveforms (profiles) and quantifies their mutual influences to maximise the cooling capacity of a La–Fe–Si-based AMR. The results show that, for all cases, the cooling capacity reaches a peak when both profiles are considered synchronised and have the same high and low periods. When some sort of phase lag is present, the drop in cooling capacity is smaller if the fluid blow is delayed with respect to the magnetic profile. In the case of trapezoidal waveforms, the cooling capacity increases with the decrease of the ramp periods, i.e., as the flow approaches a square wave. •Analysis of flow and magnetic field waveforms and the performance of La–Fe–Si AMRs.•The cooling capacity peaks when the profiles are synchronised and have equal periods.•The cooling capacity reduces less when the magnetic profile precedes the fluid blow.•The cooling capacity increases when the flow waveform approaches a square wave.
ISSN:1359-4311
DOI:10.1016/j.applthermaleng.2022.119581