A low-power CT 2nd order Delta Sigma modulator using a new design methodology for biomedical applications

This paper presents a low-power second-order continuous-time (CT) Delta-Sigma Modulator (DSM) using a new design methodology for biomedical applications. The proposed design methodology first implements a target block with the highest power consumption at a transistor level before optimizing the DSM...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of electronics and communications 2021-07, Vol.137, p.153779, Article 153779
Hauptverfasser: Hemmati, Firoz, Najafi Aghdam, Esmaeil
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper presents a low-power second-order continuous-time (CT) Delta-Sigma Modulator (DSM) using a new design methodology for biomedical applications. The proposed design methodology first implements a target block with the highest power consumption at a transistor level before optimizing the DSM coefficients. We are also able to reduce the area usage by appropriate limitations on the DSM range in the proposed design process. The DSM was implemented using the genetic algorithm (GA) and appropriate chopping techniques in our design process. The design was implemented in 0.18um CMOS technology by using a 0.083 mm2 layout, with a maximum SNDR and dynamic range of 94.28 and 100 dB, respectively, for a 2 kHz bandwidth and 32.34uW power consumption.
ISSN:1434-8411
1618-0399
DOI:10.1016/j.aeue.2021.153779