Design and optimization of a 2 MeV X-band side-coupled accelerating structure

Purpose As the development of smaller accelerators technique, an X-band bi-period side-coupled accelerating structure has been designed for medical use. Methods The structure’s working frequency is 9.3 GHz. π / 2 mode is chosen for the structure’s stability. There are 11 accelerating cells and 10 co...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Radiation detection technology and methods 2017-12, Vol.1 (2), Article 10
Hauptverfasser: Hao-Wei, Yuan, Mi, Hou, Bin, Gao
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose As the development of smaller accelerators technique, an X-band bi-period side-coupled accelerating structure has been designed for medical use. Methods The structure’s working frequency is 9.3 GHz. π / 2 mode is chosen for the structure’s stability. There are 11 accelerating cells and 10 coupling cells, the first 5 of the accelerating cells work as non-light velocity part ( β of the electron from 0.17 to 0.94), while the other 6 work as light velocity part. After CST simulation, the coupling constant between accelerating cells and coupling cells is 5%, and efficient shunt impedance is 142 M Ω / m . To feed power into the structure, a coupler is designed in the middle of the structure and the coupling coefficient is 1.4. Results After optimization, the particle’s capture efficiency is more than 30%, the particle energy is 2 MeV and the peak current is 60 mA, with the magnetron’s input power being 0.32 MW. Conclusion X-band side-coupled accelerator efficiency is high and is a more optimized design. This design is very meaningful for the development of smaller accelerators technique.
ISSN:2509-9930
2509-9949
DOI:10.1007/s41605-017-0010-6