New UPLC–MS/MS method for simultaneous determination of irbesartan and hydrochlorthiazide in human plasma

Ultra-performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) is a preeminent analytical tool for rapid biomedical analysis with the objective of reducing analysis time and maintaining good efficiency. In this study a simple, rapid, sensitive and specific ultra-performance liquid chr...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the Iranian Chemical Society 2014-12, Vol.11 (6), p.1579-1586
Hauptverfasser: Zargar, Seema, Wani, Tanveer Ahmad
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Ultra-performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) is a preeminent analytical tool for rapid biomedical analysis with the objective of reducing analysis time and maintaining good efficiency. In this study a simple, rapid, sensitive and specific ultra-performance liquid chromatography–tandem mass spectrometry method was developed and validated for quantification of the angiotensin II receptor antagonist, irbesartan and hydrochlorthiazide in human plasma. After a simple protein precipitation using methanol and acetonitrile, irbesartan, hydrochlorthiazide and internal standard (IS) telmisartan were separated on Acquity UPLC BEH™ C18 column (50 × 2.1 mm, i.d. 1.7 μm, Waters, USA) using a mobile phase consisting of acetonitrile:10 mM ammonium acetate:formic acid (85:15:0.1 % v/v/v) pumped at a flow rate of 0.3 mL/min and detected by tandem mass spectrometry with negative ion mode. The ion transitions recorded in multiple reaction monitoring mode were m / z 427.2 → 193.08 for irbesartan, m / z 295.93 → 268.90 for hydrochlorthiazide and m / z 513.2 → 287.14 for IS. The assay exhibited a linear dynamic range of 30–500 ng/mL for irbesartan and 1–500 ng/mL in human plasma with good correlation coefficient of (0.996) and (0.997) and with a limit of quantitation of 30  and 1 ng/mL for irbesartan and hydrochlorthiazide, respectively. The intra- and inter-assay precisions were satisfactory; the relative standard deviations did not exceed 10.13 % for irbesartan and 11.14 % for hydrochlorthiazide. The proposed UPLC–MS/MS method is simple, rapid and highly sensitive, and hence it could be reliable for pharmacokinetic and toxicokinetic study in both animals and humans.
ISSN:1735-207X