Ultrasonic plastification speed of polymer and its influencing factors

The melt filling difficulty in micro cavity is one of the main challenges for micro-injection molding (MIM). An approach employing ultrasound in MIM was proposed. The approach was extensively studied through experiments with a home-made experimental ultrasonic plastification device. The results of t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Central South University 2012-02, Vol.19 (2), p.380-383
1. Verfasser: 蒋炳炎 胡建良 李俊 刘小超
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The melt filling difficulty in micro cavity is one of the main challenges for micro-injection molding (MIM). An approach employing ultrasound in MIM was proposed. The approach was extensively studied through experiments with a home-made experimental ultrasonic plastification device. The results of the experiments show that polymer ultrasonic plastification speed increases with ultrasonic supply voltage and plastification pressure. When the ultrasonic supply voltage is 200 V and the plastification pressure is 2.0 MPa, the polymer ultrasonic plastification speed reaches the maximum value of 0.111 1 g/s. The results also indicate that the ultrasonic cavitation effect is the most significant effect of all the three effects during polymer ultrasonic plastification process.
ISSN:1005-9784
2095-2899
2227-5223
DOI:10.1007/s11771-012-1015-4