Determination of fluoride in human whole blood and urine by gas chromatography-mass spectrometry
We developed a simple and sensitive method for determination of fluoride in human whole blood and urine using gas chromatography-mass spectrometry (GC-MS). Fluoride was alkylated with pentafluorobenzyl bromide in a mixture of acetone and phosphate buffer (pH 6.8). The derivative obtained was analyze...
Gespeichert in:
Veröffentlicht in: | Forensic toxicology 2008-06, Vol.26 (1), p.23-26 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We developed a simple and sensitive method for determination of fluoride in human whole blood and urine using gas chromatography-mass spectrometry (GC-MS). Fluoride was alkylated with pentafluorobenzyl bromide in a mixture of acetone and phosphate buffer (pH 6.8). The derivative obtained was analyzed by GC-MS in the positive-ion electron-impact mode. The lower limit of detection for the compound was 0.5 mg/l for both matrices. The calibration curve for fluoride was linear over the concentration range of 1–100 mg/l. The precision and accuracy of the method were evaluated, and relative standard deviation was within 10%. Using this method, levels of fluoride in whole blood and urine were determined in a case of poisoning caused by hydrofluoric acid exposure. |
---|---|
ISSN: | 1860-8965 1860-8973 |
DOI: | 10.1007/s11419-008-0043-0 |