Blood concentrations of cefuroxime in cardiopulmonary bypass surgery

Objectives Patients with coronary artery bypass graft (CABG) surgery are at risk for severe postoperative infections. Prophylactic cefuroxime may help to reduce this risk, however sufficient concentrations, i.e. above the breakpoint (32 mg/L), are mandatory. The aim of this study is to evaluate the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of clinical pharmacy 2013-10, Vol.35 (5), p.798-804
Hauptverfasser: Bertholee, Daphne, ter Horst, Peter G. J., Hijmering, Michel L., Spanjersberg, Alexander J., Hospes, Wobbe, Wilffert, Bob
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objectives Patients with coronary artery bypass graft (CABG) surgery are at risk for severe postoperative infections. Prophylactic cefuroxime may help to reduce this risk, however sufficient concentrations, i.e. above the breakpoint (32 mg/L), are mandatory. The aim of this study is to evaluate the blood concentrations of cefuroxime during and after CABG surgery with cardiopulmonary bypass (CPB) and hypothermia, to determine the concentration of cefuroxime in sternum fluid and to evaluate possible factors of influence. Methods Seventeen patients were enrolled in this study, given 1.5 g cefuroxime at anaesthesia induction and an additional 1.5 g at start CPB. Blood samples were collected at skin incision, start CPB, every 30 min on CPB, end CPB, at wound closure and 1 h after surgery. Cefuroxime concentrations were determined by high performance liquid chromatography. Results In 47 % of the patients the cefuroxime concentration was below the breakpoint at some point during the operation and in 59 % of the patients 1 h after surgery. A statistically significant inverse correlation between estimated glomerular filtration rate and plasma cefuroxime concentrations was found ( P  = 0.034). Cefuroxime levels in the sternum are not significantly different from blood levels from the radial artery catheter, taken at approximately the same time ( P  = 0.30). Conclusions The current antibiotic regimen used did not maintain cefuroxime concentrations above the breakpoint throughout the operation, suggesting insufficient antibiotic prophylaxis. Further research to other antibiotic regimes is therefore necessary.
ISSN:2210-7703
2210-7711
DOI:10.1007/s11096-013-9810-z