Variable desorbent strength: influence on SMB operating conditions and performance
The aim of this work was to evaluate the role of desorbent selectivity variation on the tuning and the performance of a SMB process. For this purpose a separation regions study in the case of a four-zones non-linear transfer limited SMB was carried out. The SMB unit was modelled considering the equi...
Gespeichert in:
Veröffentlicht in: | Adsorption : journal of the International Adsorption Society 2011-02, Vol.17 (1), p.39-48 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The aim of this work was to evaluate the role of desorbent selectivity variation on the tuning and the performance of a SMB process. For this purpose a separation regions study in the case of a four-zones non-linear transfer limited SMB was carried out. The SMB unit was modelled considering the equivalent True Moving Bed (TMB). A set of 11 desorbents with different strength was considered: 3 desorbents with constant strength and 8 desorbents with variable strength. For each system, the optimal operating conditions are determined using the separation regions approach, with plots in both (Q
2
, Q
F
) and (Q
4
, Q
D
) planes. Depending on the separation considered, a variable selectivity desorbent can lead to an improvement or can be detrimental to process performances. A careful choice of desorbent selectivity (either constant or variable) is then crucial to achieve maximal process performance. |
---|---|
ISSN: | 0929-5607 1572-8757 |
DOI: | 10.1007/s10450-010-9285-3 |