Sensitive voltammetric determination of herbicide terbutryn using solid electrodes based on silver amalgam and boron-doped diamond
The applicability of the mercury meniscus modified and polished silver solid amalgam electrode (m-, p-AgSAE) and boron-doped diamond electrode (BDDE) has been investigated for voltammetric analysis of herbicide terbutryn. Cyclic voltammetry and direct current voltammetry has been used for study of t...
Gespeichert in:
Veröffentlicht in: | Monatshefte für Chemie 2016-01, Vol.147 (1), p.207-217 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The applicability of the mercury meniscus modified and polished silver solid amalgam electrode (m-, p-AgSAE) and boron-doped diamond electrode (BDDE) has been investigated for voltammetric analysis of herbicide terbutryn. Cyclic voltammetry and direct current voltammetry has been used for study of the voltammetric behavior of the analyzed substance depending on pH of supporting electrolyte and scan rate. Differential pulse voltammetry under the optimized experimental conditions has been applied for terbutryn determination using all tested electrodes with the limits of detection 2.9 × 10
−8
mol dm
−3
(m-AgSAE), 4.3 × 10
−9
mol dm
−3
(p-AgSAE), and 1.8 × 10
−7
mol dm
−3
(BDDE), respectively. Calculated values of relative standard deviations of repeated determinations (
n
= 5) in various concentration levels of terbutryn did not exceed 5 % for either of the tested electrodes. Finally, the developed methods have been successfully used in the analysis of the model samples. The obtained results were compared also with those achieved using hanging mercury drop electrode.
Graphical abstract |
---|---|
ISSN: | 0026-9247 1434-4475 |
DOI: | 10.1007/s00706-015-1556-y |