Comments on “Microsystem Technologies, (2019) 25: 609–620”
This commentary shows that the dimensionless thermal slip parameter (β 2 * ) and the dimensionless concentration slip parameter (β 3 * ) are dimensional. Appropriate correct forms of β 2 * and β 3 * are given. Also, the second elasticity parameter (E 2 ) is dimensional. An appropriate correct form o...
Gespeichert in:
Veröffentlicht in: | Microsystem technologies : sensors, actuators, systems integration actuators, systems integration, 2021-07, Vol.27 (7), p.2863-2864 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This commentary shows that the dimensionless thermal slip parameter (β
2
*
) and the dimensionless concentration slip parameter (β
3
*
) are dimensional. Appropriate correct forms of β
2
*
and β
3
*
are given. Also, the second elasticity parameter (E
2
) is dimensional. An appropriate correct form of E
2
is given. |
---|---|
ISSN: | 0946-7076 1432-1858 |
DOI: | 10.1007/s00542-020-04992-6 |