Total breast reconstruction with fat graft after serial expander deflation: a case series
Fat graft popularity has increased over the last few decades, finding a widespread pattern of application in oncological reconstruction, wound therapy and cosmetic surgery. Recently, the fat graft has been used for breast volume replacement after skin modelling by conventional tissue expanders posit...
Gespeichert in:
Veröffentlicht in: | European journal of plastic surgery 2019-10, Vol.42 (5), p.439-445 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Fat graft popularity has increased over the last few decades, finding a widespread pattern of application in oncological reconstruction, wound therapy and cosmetic surgery. Recently, the fat graft has been used for breast volume replacement after skin modelling by conventional tissue expanders positioned during mastectomy or after forced removal of prostheses due to complications. Our purpose was to assess fat grafting feasibility and safety, indicating its low rate of complications. We retrospectively analysed 7 patients treated with autologous fat grafts after oncological surgery for breast cancer. Patients not eligible for implant reconstruction and patients who refused implants were included. We analysed age, BMI (Body Mass Index), expansion rate and grafting data (session numbers, injected volume in each session and complication rates). Clinical examinations were performed every 6 months for 1 year after complete reconstruction to evaluate adipose tissue reabsorption and, eventually, further required fat grafting sessions. The aesthetic outcomes were excellent in all of the patients in our series. According to patient surveys, the satisfaction rate was very high. The filled expanders’ final volumes varied from 270 to 630 mL (average: 420 mL). The number of fat grafting sessions ranged between 2 and 3 (average 2.43), and the injected grafting volume during each session varied from 35 to 300 ml (average 175.43 ml). Expander deflation during each surgery session varied from 50 to 270 ml (average 100.63). No complications were reported. Our technique is useful and innovative and leads to good aesthetic results with shorter hospital recovery and low complications rates, compared to major reconstructive surgery. Moreover, the oncological safety appears to be uncompromised. Therapeutic, IV. |
---|---|
ISSN: | 0930-343X 1435-0130 |
DOI: | 10.1007/s00238-019-01526-w |