HLA-B27 determination using serological methods. A comparison of enzyme immunoassay and a microlymphocytotoxic test with flow cytometry and a molecular biological assay
Typing for HLA-B27 is routinely performed in patients with seronegative spondarthritides. Besides the microlymphocytotoxic test (MLCT), other serological techniques have been developed such as enzyme immunoassays (EIA) using serum or plasma as a source for the determination of soluble HLA-B27 (sHLA-...
Gespeichert in:
Veröffentlicht in: | Rheumatology international 1996, Vol.16 (3), p.95-100 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Typing for HLA-B27 is routinely performed in patients with seronegative spondarthritides. Besides the microlymphocytotoxic test (MLCT), other serological techniques have been developed such as enzyme immunoassays (EIA) using serum or plasma as a source for the determination of soluble HLA-B27 (sHLA-B27) and flow cytometric (FC) methods. The aim of the present study was to check the accuracy and reliability of the EIA for sHLA-B27 in comparison to the MLCT using antibodies against HLA-B27 and cross-reacting specificities (CRS), as well as an FC method and a molecular biological method. Any discrepant results should be typed with the MLCT using a complete panel of anti-HLA-class I antibodies, with FC and with a molecular biological technique. The EIA should also be repeated in those patients, using serum and plasma from a new venipuncture. In 81 patients with rheumatic disorders, the EIA and the MLCT using antibodies against HLA-B27 and CRS were performed. Based on the MLCT with a complete panel of anti-HLA-class I antibodies as a standard, discrepant test results were obtained for 9 out of 81 patients with the MLCT using antibodies against HLA-B27 and CRS and with the EIA. The following wrong results occurred: in the MLCT with anti-HLA-B27 and CRS, there were two false-negative results; in the EIA there were four false-negative and one false-positive results; one sample was undeterminable. In comparison with the MLCT, including the complete panel of HLA-class I antibodies, as well as with a molecular biological technique, typing with FC showed a complete concordance. Our investigations demonstrated that for routine typing for HLA-B27 the MLCT cannot be replaced by EIA because of a significant number of mistypings. The MLCT performed only with antibodies against HLA-B27 and CRS may also lead to typing errors. No errors were detected using flow cytometry. If only serological methods can be performed in a laboratory a combination of flow cytometry and MLCT could therefore enhance the safety of HLA-B27 typing. |
---|---|
ISSN: | 0172-8172 1437-160X |
DOI: | 10.1007/BF01409980 |