Viability of resistance thermometers under reactor conditions

The viability of six commercial resistance thermometers is examined under reactor conditions; the sensitive element was P1-2 platinum wire of diameter 50 /mu/m. The resistances R/sub 0/ of the thermometers at 0/degree/C were 46.00/plus or minus/0.02 /OMEGA/while the ratios were R/sub 100//R/sub 0/.1...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Sov. At. Energy (Engl. Transl.); (United States) 1980-05, Vol.48 (5), p.340-341
Hauptverfasser: Korotenko, M. N., Salamakha, V. A., Slesarevskii, S. O., Maksimenko, V. P.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The viability of six commercial resistance thermometers is examined under reactor conditions; the sensitive element was P1-2 platinum wire of diameter 50 /mu/m. The resistances R/sub 0/ of the thermometers at 0/degree/C were 46.00/plus or minus/0.02 /OMEGA/while the ratios were R/sub 100//R/sub 0/.1.391/plus or minus/0.0007. The design and manufacturing technology have been described. The thermometers were irradiated in a VVR-M reactor. The thermometers were calibrated before and after irradiation outside the reactor by the reference-point method at temperatures of l00, 231.8, and 327.2/degree/C. 7 refs.