Viability of resistance thermometers under reactor conditions
The viability of six commercial resistance thermometers is examined under reactor conditions; the sensitive element was P1-2 platinum wire of diameter 50 /mu/m. The resistances R/sub 0/ of the thermometers at 0/degree/C were 46.00/plus or minus/0.02 /OMEGA/while the ratios were R/sub 100//R/sub 0/.1...
Gespeichert in:
Veröffentlicht in: | Sov. At. Energy (Engl. Transl.); (United States) 1980-05, Vol.48 (5), p.340-341 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The viability of six commercial resistance thermometers is examined under reactor conditions; the sensitive element was P1-2 platinum wire of diameter 50 /mu/m. The resistances R/sub 0/ of the thermometers at 0/degree/C were 46.00/plus or minus/0.02 /OMEGA/while the ratios were R/sub 100//R/sub 0/.1.391/plus or minus/0.0007. The design and manufacturing technology have been described. The thermometers were irradiated in a VVR-M reactor. The thermometers were calibrated before and after irradiation outside the reactor by the reference-point method at temperatures of l00, 231.8, and 327.2/degree/C. 7 refs. |
---|---|