Pin-hole changes after external fixation of tubular bone

K-wire-pin-induced changes in cortical bone were studied in the intact rabbit tibiofibular bone. Using a bilateral external fixator two pairs of pins were applied under compression (10 kp), under distraction (10 kp), and in a neutralization sense. After defined intervals the pin-holes were investiga...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Archives of Orthopaedic and Traumatic Surgery 1985-01, Vol.104 (2), p.118-120
Hauptverfasser: Aalto, K, Slätis, P, Karaharju, E, Waris, P
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:K-wire-pin-induced changes in cortical bone were studied in the intact rabbit tibiofibular bone. Using a bilateral external fixator two pairs of pins were applied under compression (10 kp), under distraction (10 kp), and in a neutralization sense. After defined intervals the pin-holes were investigated macroscopically and radiologically. Reactive and resorptive changes were present in 101 of 576 (17.5%) pin-holes, infection in 13 (2.3%) pin-holes. Changes were significantly more frequent in the distal pin-holes. The appearance of the pin-holes was not influenced by the type of external fixation used nor did the occurrence depend on the duration of metal implantation.